The DECS-100-B15 is a microprocessor-based digital automatic voltage regulator (AVR) in the Woodward DECS-100 family — originally the Basler Electric DECS-100 fifth-generation digital excitation control system. It is designed for brushless excited synchronous generators up to approximately 5 MW, where it closes the loop between measured terminal voltage and the generator field: more excitation when voltage falls, less when it rises.The DECS-100-B15 is the 5 A CT-secondary configuration of the series. It measures terminal voltage through PT inputs, measures stator current through a 5 A CT input, and drives the exciter field with a 63 VDC / 7 A continuous PWM output — rising to 135 VDC / 15 A for 10 seconds when system voltage collapses and the generator needs to hold it up. Four control modes (AVR, FCR, VAR, PF) cover standalone island operation, utility paralleling, and everything in between.
Application Scenarios
A combined-heat-and-power plant operates a 4 MW gas engine generator in daily parallel with the utility. The original analogue AVR was a Basler AVC63-series card, adjusted in the field with a screwdriver against two potentiometers. The symptom was familiar to the operators: after a synchronising close, the generator would sit at the wrong reactive import, and the engineer would have to bias the setpoint manually from the synchroniser until the var meter settled. It was not unsafe, but it was imprecise — and every manual adjustment was an undocumented change to the excitation settings.Retrofitting with a DECS-100-B15 put the generator into VAR control mode with a -3 to +3 VDC bias input driven by the plant synchroniser. The bias maps to ±30 % of rated voltage, so the central system now moves the generator’s reactive output directly without anyone at the excitation cubicle. Steady-state regulation holds at ±0.25 % from no-load to full-load, and the 1-cycle response time means a load step is corrected before the plant instruments have finished displaying it. After commissioning, the generator holds its dispatched vars without operator intervention, and the commissioning file is a downloaded parameter set rather than a photograph of two potentiometer positions.The same retrofit rationale applies to a diesel standby set that has to pick up an emergency bus. The soft-build excitation ramp brings terminal voltage up smoothly during run-up, avoiding the overvoltage transient that trips sensitive electronic loads; if a PT fuse blows, loss-of-sensing logic transfers the regulator to manual field-current control rather than dropping the load.
Parameter
| Main Parameters | Value / Description |
|---|---|
| Product Model | DECS-100-B15 |
| Manufacturer | Basler Electric (now Woodward Power Generation Controls) |
| Product Category | Digital automatic voltage regulator (AVR) / digital excitation control system |
| Series | DECS-100 fifth-generation digital AVR |
| Suffix Meaning | B15 = 5 A AC CT secondary input (the suffix identifies the CT configuration) |
| Control Power Input | 88–250 VAC, single-phase or three-phase, 50–400 Hz |
| Minimum Build-Up Voltage | 6.0 VAC — voltage below which the regulator cannot establish excitation |
| Voltage Sensing Inputs | 100/120, 200/240, 400/480, 600 VAC; single-phase or three-phase |
| Frequency | 50 Hz and 60 Hz systems; sensing valid to 400 Hz |
| Current Sensing Input | 5 A AC CT secondary (B15); 1 A variant is the A15 suffix |
| Voltage Regulation Accuracy | ±0.25 % from no-load to full-load (rated PF, constant frequency) |
| Harmonic Tolerance | ±0.5 % at 40 % THD with three-phase sensing |
| Response Time | Within 1 power-system cycle |
| Continuous Excitation Output | 63 VDC at 7.0 A DC |
| Boost Excitation Output | 135 VDC at 15 A DC for 10 seconds |
| Minimum Field (Magnet) Resistance | 9 Ω (standard); verify against the specific suffix and exciter data |
| Bias (Accessory) Input | -3 to +3 VDC; setting offset ±30 % of rated voltage |
| Control Modes | AVR (automatic voltage regulation), FCR (field current regulation / manual), VAR control, PF (power factor) control |
| V/Hz Limiter | Adjustable 0–3 × V/Hz — limits excitation as frequency falls to protect the core |
| Protection Functions | Overexcitation limit (OEL), underexcitation limit (UEL), V/Hz limiting, over- and undervoltage, loss of sensing, excitation overcurrent and overvoltage lockout, soft-start build-up |
| Parallel Compensation (Droop) | 0–10 % |
| Configuration | BESTCOMS software via RS-232 / DB-9 port; parameter sets downloaded and SOE records retrieved |
| Alarm Output | Form-A (SPDT) dry contact; 120/240 VAC, 7 A continuous, 30 A closing surge for 0.2 s |
| Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage Temperature | -40 °C to +85 °C |
| Vibration / Shock | Up to 5.0 G (53–500 Hz); 20 G shock |
| Mounting | Flush panel mount, metal enclosure |
| Enclosure Rating | IP20 (module only) |
| Physical Size | 135.6 × 274.8 × 72.1 mm (5.34 × 10.82 × 2.84 in) |
| Weight | Approx. 1.09–1.10 kg |
| Certifications | UL 6200, CSA, CE, EAC; marine type approvals: BV, DNV·GL, RMRS |
| Country of Origin | USA |