Application Scenarios:
In distributed generation, cogeneration, or peak-shaving power plants, sudden motor starts, variable frequency drives, or grid paralleling transitions can cause voltage dips, circulating reactive current, and nuisance trips. Deploying DECS-100-B15 gives plant engineers fast closed-loop excitation control, voltage matching, and programmable stability profiles suited for single-unit or paralleled generator buses. By keeping generator voltage and reactive power tightly regulated during load steps, DECS-100-B15 protects connected equipment, stabilizes bus quality, and supports reliable parallel operation.
Parameter:
| Main Parameters | Value/Description |
| Product Model | DECS-100-B15 |
| Manufacturer | Woodward / Basler Electric (DECS-100 Series) |
| Product Category | Digital Automatic Voltage Regulator (AVR) / Excitation Control System |
| Continuous Field Output | 63 Vdc at 7.0 Adc PWM output (minimum 9 Ω field resistance; 10-second forcing up to 135 Vdc / 15 Adc on 200 Vac power input) |
| Operating Power Input | 88 to 250 Vac, 1-phase or 3-phase, 50 to 400 Hz (650 VA burden; supports shunt or PMG excitation power) |
| Voltage Sensing Input | 100/120, 200/240, 400/480, or 600 Vac (1-phase or 3-phase, 50/60 Hz, <1 VA per phase burden) |
| Regulation Accuracy | ±0.25% from no-load to full-load; ±0.5% up to 40% THD (six-thyristor nonlinear load profiles) |
| Control & Protection Modes | AVR, manual (FCR), VAR/PF regulation, voltage matching, soft start, 0–3X V/Hz limiting, and loss-of-sensing transfer |
| Communication & Setup | RS-232 (DB-9) port for PC configuration via BESTCOMS software plus analog/contact bias inputs |
| Operating Temperature | -40°C to +70°C (-40°F to +158°F) rated industrial operating range |
| Dimensions & Weight | Approx. 135.6 mm W x 274.8 mm H x 72.1 mm D (5.34″ x 10.82″ x 2.84″); ~1.10 to 1.31 kg |
| Vibration & Certifications | 20 G shock, MIL-STD-810E salt fog, UL recognized, CSA, CE, and marine approvals |
Technical Principles and Innovative Values:
- Innovation Point 1: DECS-100-B15 drives a high-speed PWM power stage rated at 63 Vdc and 7.0 Adc continuous with strong short-term forcing capability, delivering sub-cycle dynamic response to load changes. Compared with older analog regulators that drift with age or struggle during rapid step loads, DECS-100-B15 maintains ±0.25% steady-state regulation and supports 20 standard stability selections plus one customizable profile.
- Innovation Point 2: Built to handle harsh electrical waveforms, DECS-100-B15 sustains ±0.5% regulation accuracy even up to 40% total harmonic distortion (THD) typical of six-thyristor drive loads. Direct sensing up to 600 Vac (single- or three-phase) reduces external potential transformer requirements in many installations while keeping metering and paralleling adjustments fine-grained.
- Innovation Point 3: Encapsulated in a rugged potted assembly rated from -40°C to +70°C with high shock and vibration resistance, DECS-100-B15 resists moisture, dust, and mechanical stress in generator enclosures. In remote, marine, or industrial power skids where ambient conditions fluctuate sharply, DECS-100-B15 reduces board-level environmental failures and extends service life.
WhatsApp:+86 18005022363 WeChat: +86 18005022363
Email: