Product Overview
The Allen-Bradley 1606-XL480EPT is a single-phase switched-mode power supply from Rockwell Automation’s Bulletin 1606-XL standard series, built to deliver a regulated 24 V DC rail for PLCs, I/O modules, sensors, actuators, network switches and the general population of 24 V loads in an industrial control cabinet. Rated at 480 W with 20 A of continuous output current at 24 V, the Allen-Bradley 1606-XL480EPT is sized to carry a medium-to-large panel on its own, and its output can be trimmed across a 24 to 28 V DC range so the rail can be raised slightly to compensate for voltage drop on long cable runs to remote I/O.What separates this model from a basic panel supply is the feature set carried in the “EPT” designation: active power factor correction, remote shutdown signal terminals, and overload behaviour that can be configured for continuous current or hiccup mode. That last point matters more than it sounds — in continuous-current mode the Allen-Bradley 1606-XL480EPT keeps feeding well above rated current during a load start-up instead of switching off, which lets awkward loads such as DC-DC converters, solenoid banks and small motors start reliably and lets downstream protective devices trip selectively. It is also designed for parallel operation, so two units can share a load for redundancy or additional capacity.Input is 100–120 / 200–240 V AC with automatic selection at 47–63 Hz, so the same unit works on 120 V and 230 V grids without a tap or jumper. Cooling is by natural convection with no fan, and the Allen-Bradley 1606-XL480EPT carries worldwide industrial approvals, making it a straightforward choice for machine builders shipping globally and for maintenance teams replacing like-for-like in existing panels.
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | 1606-XL480EPT (Series A) |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Product Type | Switched-mode DIN rail power supply, Bulletin 1606-XL standard series |
| Rated Output Power | 480 W (continuous at ambient up to 60 °C) |
| Output Voltage | 24 V DC nominal, adjustable 24 to 28 V DC |
| Output Current | 20 A at 24 V DC; 18 A at 28 V DC |
| Input Voltage | AC 100–120 V / 200–240 V auto select |
| Input Frequency | 47 to 63 Hz |
| Input Current | Less than 10 A at 115 V AC; less than 5 A at 230 V AC |
| Efficiency | Approximately 90 % |
| Hold-Up Time | 30 ms at 120 V AC and 230 V AC; 15 ms at 100 V AC |
| Output Ripple | Low ripple, typically below 50 mVpp |
| Special Features | Active power factor correction (PFC), remote shutdown terminals, power boost reserve, parallel operation capability |
| Overload Behaviour | Selectable: continuous current mode or hiccup mode |
| Power Factor Correction | Active PFC, integrated PFC choke |
| Signalling | DC OK LED indication; remote shutdown signal terminals (Remote Shutdown 1 and 2) |
| Protection Functions | Overload, over-voltage, short-circuit and over-temperature shutdown with automatic restart |
| Cooling Method | Natural convection, fanless |
| Operating Temperature | −25 °C to +70 °C, derated above +60 °C |
| Storage Temperature | −25 °C to +85 °C |
| Relative Humidity | 5 to 95 %, non-condensing |
| Protection Class | IP20, for installation inside a control cabinet |
| Mounting | 35 mm DIN rail (DIN-35) |
| Connection Type | Screw terminals, front-accessible |
| Dimensions (H × W × D) | Approx. 124 × 220 × 102 mm |
| Weight | Approx. 2.1 to 2.5 kg |
| MTBF | Approximately 519,000 hours |
| Certifications | cULus, cURus, CE, UL 508, IEC/EN 60950, EN 50178, RoHS |
| Country of Origin | USA |
| Lifecycle Status | Discontinued by manufacturer |