Application Scenarios
In a water treatment plant in Taiyuan, this relay is installed in a motor control center (MCC) protecting a 45 kW cooling water pump motor. It monitors the three-phase current. If the pump gets clogged, causing the current to rise to 120% of the set value for over 30 seconds, the TA200 DU90 automatically opens its control contact, dropping the contactor and shutting down the pump before the motor windings overheat.
Parameter
| Main Parameters | Value/Description |
|---|---|
| Product Model | TA200 DU90 |
| ABB Order Code | 3BHE010751R0101 |
| Rated Operational Voltage | 690 V AC |
| Setting Current Range | 66 – 90 A (Continuously adjustable dial) |
| Trip Class | 10A (Standard trip characteristic for normal starting motors) |
| Number of Poles | 3 |
| Auxiliary Contacts | 1 NO (97-98) + 1 NC (95-96) |
| Reset Mode | Manual / Automatic (Selectable via side lever) |
| Ambient Temperature | -25 °C to +55 °C (Ambient compensated) |
| Mounting | Direct clip-on to ABB A-line contactors (e.g., A75, A80) or single mounting kit |
| Protection Features | Overload, Phase Failure (Unbalance) |
Technical Principles and Innovative Values
- Innovation Point 1: Ambient Temperature Compensation for Stable Protection: Unlike basic thermal relays whose trip point drifts with cabinet temperature, the TA200 DU90 features automatic ambient temperature compensation. This means whether your Taiyuan facility is in a hot summer (+40°C) or a cold winter (-10°C) environment, the relay’s trip current remains stable relative to the motor’s actual thermal capacity. This prevents nuisance tripping in heat or under-protection in cold weather.
- Innovation Point 2: Trip-Free Mechanism for Safety: The relay incorporates a trip-free mechanical design. Once it trips due to an overload, even if the reset button is held down forcibly, the contacts will not re-close until the bimetallic strips have cooled down and the fault is cleared. This “mechanical memory” ensures the motor cannot be restarted prematurely into a fault condition, protecting both the motor and the operator.
- Innovation Point 3: Integrated Phase Failure Protection: The relay’s design provides inherent phase loss/unbalance protection. If one phase of the motor supply is lost, the increased current in the remaining phases causes the bimetallic strips to heat up asymmetrically, triggering a faster trip than a balanced overload. This protects the motor from single-phasing damage, a common cause of motor failure in industrial settings.
Application Cases and Industry Value
Case 1: Coal Mine Ventilation Fan, Shanxi Province. A mine ventilation fan driven by an 80A motor was protected by a TA200 DU90. During a period of high dust concentration, the fan blade imbalance led to a gradual current rise. The relay’s Class 10A characteristic allowed the motor to start under heavy load (high inertia) without tripping, but reliably disconnected it after 2 minutes of sustained overload, preventing a catastrophic motor seizure and ensuring mine air quality safety.Case 2: Steel Plant Conveyor System. In a continuous casting conveyor, multiple TA200 DU90 relays were used. The manual reset mode (selected via the side lever) was enforced as a safety procedure. After an overload trip, maintenance personnel were required to physically inspect the conveyor belt for jams before pressing the reset button, enforcing a “lockout-tagout” discipline and preventing remote automatic restarts into a dangerous condition.