The Yokogawa SSC10D-S2111​ is a high-integrity, duplexed safety control unit that forms the deterministic processing core of the ProSafe-RS Safety Instrumented System. Engineered by Yokogawa for safety-critical automation, this 19-inch rack-mount controller executes complex safety logic for emergency shutdown, burner management, fire and gas, and high-integrity pressure protection applications. It is purpose-built for continuous process industries where functional safety, system availability, and uninterrupted operation cannot be compromised.At the heart of the Yokogawa SSC10D-S2111​ is a dual-processor 1oo2D architecture. Two independent CPUs execute the same safety application in parallel and continuously cross-compare results. If a fault is detected in one processor, the system performs a bumpless, automatic switchover in one millisecond or less, keeping the safety function fully active. This redundant design ensures that no single hardware failure can disable the protection logic or cause an unintended process shutdown.The Yokogawa SSC10D-S2111​ is fully integrated with the ProSafe-RS platform and communicates over dual-redundant Vnet/IP and ESB buses. It supports seamless engineering and operator integration with Yokogawa CENTUM VP and CENTUM CS 3000 distributed control systems. Certified to SIL3 per IEC 61508 and IEC 61511, the controller delivers predictable scan times, comprehensive self-diagnostics, and extensive event recording, making it a trusted safety solution for refineries, petrochemical plants, power stations, and offshore production facilities.

Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description

 

Technical Specifications

Parameter Name Parameter Value
Product Model SSC10D-S2111
Manufacturer Yokogawa Electric Corporation
Product Type Duplexed Safety Control Unit
System Platform ProSafe-RS SIS
Compatible DCS CENTUM VP, CENTUM CS 3000
Processor MIPS R5000, 32-bit RISC
Redundancy Architecture Dual CPU, 1oo2D
Main Memory 32 MB
Safety Integrity Level SIL3 (IEC 61508 / IEC 61511)
Safety Logic Response Time ≤10 ms
Redundancy Switchover Time ≤1 ms, bumpless
Communication Interfaces Dual-redundant Vnet/IP, 100 Mbps
Backplane Bus Dual-redundant ESB bus, 128 Mbps
Node Expansion Up to 9 Safety Node Units (SNB10D)
Local I/O Modules Up to 8 modules
Power Supply 100–120 V AC, 50/60 Hz
Power Consumption Approximately 200 VA
Operating Temperature -10°C to +55°C
Storage Temperature -20°C to +70°C
Humidity 5% to 95% RH, non-condensing
Dimensions (W × H × D) 482.6 × 88.1 × 266 mm
Weight Approximately 8.5 kg
Mounting Method 19-inch rack mount
Programming Software SCS Logic Designer (IEC 61131-3)
Required License CFS1100 Safety Control Functions Package
Certifications TÜV, CE, ATEX, IECEx, CSA, UL
Optional Features IRIG-B GPS time synchronization

 

Main Features and Advantages

The defining strength of the Yokogawa SSC10D-S2111​ is its dual-processor fault-tolerant architecture. By running two processors in parallel and continuously verifying their outputs, the controller delivers true 1oo2D redundancy. A failure in either CPU is detected immediately and corrected through an automatic, bumpless transfer. This capability is essential for processes where an unexpected shutdown is costly and a failure to actuate is unacceptable.The Yokogawa SSC10D-S2111​ combines deterministic performance with flexible I/O expansion. Its configurable scan cycle and rapid safety logic response make it suitable for fast-acting ESD and HIPPS loops, while its ability to support up to nine safety node units allows a single controller to manage distributed safety functions across large and complex facilities.Integration is another major advantage. The controller shares the Vnet/IP backbone and engineering environment with Yokogawa DCS platforms. This unified architecture reduces configuration effort, simplifies alarm and trend management, and allows operators to monitor process control and safety functions through a common interface.Additional features include dual-redundant power supplies, dual ESB buses, non-volatile program memory with battery backup, and optional GPS-based time synchronization. Comprehensive onboard diagnostics, SOE resolution down to one millisecond, and international safety certifications further enhance the reliability and maintainability of the Yokogawa SSC10D-S2111.

Application Field

The Yokogawa SSC10D-S2111​ is purpose-designed for industries where safety and availability are mission-critical. In upstream oil and gas, it provides emergency shutdown, fire and gas voting, and high-integrity pressure protection for wells, manifolds, pipelines, and offshore platforms. Its deterministic logic execution and high-speed diagnostics ensure that hazardous conditions are detected and mitigated without delay.In refining and petrochemical facilities, the Yokogawa SSC10D-S2111​ safeguards compressors, reactors, furnaces, and distillation columns. It is equally effective in burner management systems, where precise sequencing, flame monitoring, and fuel trip logic must operate reliably under all conditions.Power generation plants use the Yokogawa SSC10D-S2111​ for turbine and generator protection, boiler safety, and critical interlock applications. Its ability to synchronize with GPS time sources also makes it valuable for sequence-of-events analysis after process upsets. Across all applications, the controller solves the dual challenge of maximizing plant availability while maintaining rigorous functional safety.