WOODWARD IRI1-I5E05D Earth Fault Relay for Isolated and Compensated Mains Protection

The WOODWARD IRI1-I5E05D is a directional earth fault relay engineered for the protection of isolated and compensated mains networks within medium voltage distribution systems. As part of Woodward’s comprehensive relay protection portfolio, the IRI1-I5E05D provides sensitive and selective detection of ground fault currents, distinguishing between forward and reverse fault directions through either the sine or cosine phase comparison method. This directional discrimination capability allows the relay to operate selectively in ring main units, parallel feeder configurations, and compensated neutral systems where non-directional earth fault protection would lack the selectivity required for reliable service continuity.Designed around the Woodward IRI1 platform, the IRI1-I5E05D measures residual current through the relay’s 1E1/1E2 current input terminals and compares its phase angle against a reference voltage applied to the L1/N1 terminals. The relay determines the tripping direction by evaluating whether the residual current leads or lags the reference voltage beyond user-defined marginal regions. When a forward-direction earth fault is detected, the relay initiates its trip sequence after the programmed time delay; for reverse-direction faults, a separate time delay setting allows coordination with upstream or downstream protective devices. The IRI1-I5E05D features independent adjustable time delays for forward and reverse directions, enabling precise grading coordination in complex distribution networks.The relay’s front panel provides clear LED status indication, including a bidirectional LED that changes from green to red as the measured phase angle crosses the marginal region boundary between forward and reverse zones. This visual feedback simplifies commissioning and fault analysis, allowing technicians to verify directional discrimination on site using test current and voltage sources. The IRI1-I5E05D is typically powered from the current transformer circuit itself in CT-powered configurations, or from an external auxiliary supply, and provides alarm and trip relay outputs for interfacing with circuit breaker trip coils, SCADA systems, and annunciator panels. Its compact design and standardized terminal layout make it suitable for retrofit installation in existing switchgear panels as well as new build applications.

Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description

 

Technical Specifications

Parameter Name Parameter Value
Parameter Name Parameter Value
Product Model IRI1-I5E05D
Manufacturer WOODWARD
Product Type Directional Earth Fault Relay
Application Isolated and Compensated Mains
Current Input Terminals 1E1 / 1E2
Voltage Reference Terminals L1 / N1
Pickup Setting 0.2 x In (adjustable)
Directional Method Sin / Cos Phase Comparison
Forward Trip Delay Adjustable (tIE> V)
Reverse Trip Delay Adjustable (tIE> R)
Test Current Level 0.4 x In
Frequency 50/60 Hz
Output Relays Alarm / Trip Contacts
Mounting Type DIN Rail / Panel Mount
Operating Temperature -20°C to +55°C (typical)
Standards IEC 60255 Series

 

Main Features and Advantages

Directional Discrimination for Selective Protection: The WOODWARD IRI1-I5E05D implements directional earth fault detection using either the sine or cosine method, evaluating the phase relationship between the residual current at terminals 1E1/1E2 and the reference voltage at terminals L1/N1. This allows the relay to distinguish between faults occurring in the forward direction (toward the protected feeder) and those in the reverse direction (toward the busbar or adjacent feeders). By setting independent trip delays for forward and reverse directions, the IRI1-I5E05D enables selective coordination in ring main and parallel feeder arrangements, ensuring that only the faulted section is isolated while healthy sections remain in service.Sensitive Pickup and Adjustable Time Delays: The relay features a pickup threshold set at 0.2 x In, providing sensitive detection of low-magnitude earth fault currents typical in compensated neutral and high-resistance grounded systems. The forward and reverse trip delays (tIE> V and tIE> R) are independently adjustable, allowing protection engineers to implement time-graded schemes that coordinate with upstream and downstream devices. This adjustability is essential in distribution networks where fault current magnitudes vary with system configuration and where selective tripping is required to maintain supply continuity.Clear Visual Status Indication: The front panel of the IRI1-I5E05D includes a bidirectional LED indicator that provides immediate visual confirmation of the detected fault direction. During normal operation or when the measured phase angle is within the forward marginal region, the LED displays green; when the angle shifts beyond the marginal region into the reverse zone, the LED changes to red. This intuitive indication simplifies commissioning, allows rapid verification of correct CT and VT polarity during commissioning, and assists maintenance personnel in diagnosing the direction of an earth fault without requiring connection to a laptop or configuration software.Robust Construction for Harsh Environments: Built to withstand the electrical and environmental stresses of industrial and utility switchgear environments, the IRI1-I5E05D features a robust enclosure with sealed terminals and internal circuitry designed to reject transients, withstand CT saturation during through-faults, and maintain accuracy across the full operating temperature range. The relay’s design complies with relevant IEC 60255 standards for electromagnetic compatibility and dielectric withstand, ensuring reliable operation in the presence of switching surges, lightning strikes, and power frequency interference common in MV distribution substations.