The Woodward 9907-135​ is an actuator driver module designed to interface between a Woodward 505 or 505E digital turbine governor and the final electro-hydraulic control element. In a turbine control loop, the governor performs the speed, load, and extraction control calculations, but it is the Woodward 9907-135​ that closes the final link—translating the governor’s low-level positioning demand into a precisely regulated current capable of driving a torque motor, proportional solenoid, or electro-hydraulic actuator (EHA). This makes the module an essential power-stage component in steam and gas turbine packages built on the proven Woodward 505 platform.The Woodward 9907-135​ accepts a control reference—typically a 4–20 mA signal, ±10 VDC command, or internal digital setpoint from the governor—and converts it into a closed-loop, high-fidelity output current. It continuously measures the actual drive current and adjusts it to match the commanded value, ensuring the actuator receives exactly the intended positioning force. Whether the load is a fuel control valve on a gas turbine, a steam admission valve on a utility turbine, or a liquid-fuel metering valve on a dual-fuel package, the Woodward 9907-135​ delivers the stable, responsive drive required for precise speed and load regulation.Engineered for the electrically demanding environment of a turbine control cabinet, the Woodward 9907-135​ incorporates short-circuit, over-current, and feedback-loss protection, along with continuous output diagnostics. Its robust design, wide operating temperature range, and signal isolation make it well suited to continuous operation in power generation, oil and gas, petrochemical, and marine propulsion applications where governor hardware is expected to perform reliably for decades.

Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description

 

Technical Specifications

Parameter Name Parameter Value
Product Model 9907-135
Manufacturer Woodward
Product Type Actuator / Valve Driver Module
Compatible Platform Woodward 505 / 505E Digital Turbine Governor
Input Signal 4–20 mA / ±10 VDC governor command
Output Type Proportional current drive for torque motor / solenoid
Output Current Range 4–20 mA or 20–160 mA (configurable)
Output Compliance Sufficient to drive EHA / proportional valve coils
Control Method Closed-loop current regulation
Protection Features Short-circuit, over-current, feedback-loss, reverse-polarity
Diagnostics Output current monitoring, coil continuity, fault status
Operating Temperature -40 °C to +85 °C
Power Supply 24 VDC system supply
Mounting Control cabinet / 505 chassis
Certifications Designed to applicable industrial EMI/RFI standards

 

Main Features and Advantages

The primary value of the Woodward 9907-135​ lies in its role as a precision power interface. The governor can calculate the ideal valve position to within a fraction of a percent, but without an accurate, stable driver stage that demand will never reach the actuator cleanly. The Woodward 9907-135​ provides closed-loop current control, meaning the actual drive current is sampled and corrected continuously—even as actuator coil resistance changes with oil temperature or ambient conditions, valve position does not drift.Closed-loop current regulation for accurate positioning:Unlike a simple voltage amplifier, the Woodward 9907-135​ regulates the current delivered to the torque motor or solenoid. This is the physically meaningful quantity for actuator force: a given current produces a given magnetic force, regardless of coil heating or supply variation. The result is repeatable, linear valve positioning—critical for stable speed control, especially during turbine start-up ramps, load changes, and fuel-transfer windows on dual-fuel engines.Built-in protection and diagnostics:The Woodward 9907-135​ monitors output current, coil continuity, and internal fault conditions. Open coils, shorted outputs, and loss of command signal are detected and can be reported to the 505E governor, which may then raise an alarm or initiate a controlled trip depending on how the actuator-fault logic is configured. This protects both the driver electronics and the expensive actuator hardware downstream, and it gives maintenance staff a clear first indicator when valve performance degrades.Rugged industrial design:Designed for turbine enclosures rather than benign office environments, the Woodward 9907-135​ tolerates wide temperature swings, vibration, humidity, and electrical noise. Its signal isolation between input and output stages helps prevent ground loops and transducer-induced disturbances from propagating into the actuator drive. These characteristics support the long service intervals and high availability expected of governor equipment in continuous-process industries.

Application Field

The Woodward 9907-135​ is used wherever a Woodward 505 or 505E governor needs to drive an electro-hydraulic final element. In steam turbine generator sets—found in captive power plants, combined heat and power (CHP), and waste-to-energy facilities—the module drives the steam admission valve, translating the governor’s speed/load control into precise valve positioning for frequency regulation and load sharing between parallel machines.In gas turbine packages, the Woodward 9907-135​ drives fuel-metering actuators, supporting start-up ramp control, acceleration limiting, and load management. For dual-fuel applications, separate driver channels may control gas and liquid-fuel valves under a single governor strategy; the driver’s stable current regulation ensures smooth, bumpless fuel transfer without combustion instability. In mechanical-drive turbines used in refineries and petrochemical plants, the module controls steam valves that regulate turbine speed to drive compressors, fans, and process pumps.The module also supports turbine control retrofit projects: when upgrading legacy mechanical or electro-hydraulic governors to a modern 505E digital platform, the Woodward 9907-135​ allows reuse of existing actuator hardware while providing the modern, closed-loop drive stage the new governor requires. This shortens outage time and preserves the investment in proven field equipment.