Description
Application Scenarios
A Pacific-region container vessel operates four diesel generator sets in a ring bus, with any two, three, or all four online depending on cargo handling and voyage condition. The ships were built with an older generation of analogue load-sharing equipment, and the symptoms had become routine: one engine would walk up to full load while another drifted toward no-load, then the chief engineer would have to retrim manually at the governor to keep the sets balanced. It was not a breakdown, so it never made a defect list — but it was burning fuel poorly and loading one crankcase disproportionately.Retrofitting the four sets with 8408-005 GLC modules and re-terminating the existing PT and CT circuits eliminated the drift. The load share line runs between the modules, so the controllers negotiate the split among themselves rather than relying on the governor trim pots. After commissioning, load imbalance between running sets stayed within one per cent across the full 0–100 % range, and the manual retrimming at each load step disappeared. The crew’s feedback was that the plant no longer needed attention after a generator was added or dropped — the 8408-005 settled it automatically.On land, the same principle applies to a remote mining camp where three generators back a utility tie. When the utility is present, the gensets run in droop and hold a fixed export or import setpoint; when the utility fails, they switch to isochronous load sharing and carry the camp together. The 8408-005 handles both modes in one device, which is what makes a clean transition possible without a changeover relay scheme.
Parameter
| Main Parameters | Value / Description |
|---|---|
| Product Model | 8408-005 |
| Manufacturer | Woodward, USA |
| Product Category | Generator Loading Control (GLC) module / precision load controller |
| Series | 8408-series LCD Generator Loading Control |
| Power Supply — DC model | 18–32 VDC, approx. 5 W consumption |
| Power Supply — AC model | Jumper-selectable 95–130 or 190–260 VAC line-to-line, 50–400 Hz, approx. 10 W consumption |
| PT Inputs | 3-phase, 95–130 or 190–260 VAC line-to-line, 50–400 Hz |
| PT Burden | 1.6 W per phase at 240 VAC; 0.4 W per phase at 120 VAC |
| CT Inputs | 3-phase, 3–7 A RMS at full load |
| CT Input Burden | 0.1 VA per phase at full load — keeps the GLC from loading the existing CT circuits |
| Load Sensing Accuracy | ±0.25 % of full-scale load (referred to CT/PT primary) |
| Load Sharing Accuracy | ±1 % of unit rating at 47–53 Hz and 57–63 Hz |
| Load Sharing Input / Line | 0–3 VDC into 25 kΩ impedance in isochronous mode; open circuit in droop mode |
| Control Modes | Isochronous load sharing (isolated bus / multiple sets); droop control (parallel to utility) |
| Operating Frequency | 50 Hz and 60 Hz systems |
| Frequency Detection | Underspeed and overspeed sensing for load control and transfer decisions |
| Display | Integrated front-panel LCD — load percentage and status visible at the cabinet |
| Isolation | Galvanic isolation between field inputs and internal logic for noise immunity |
| Operating Temperature | -40 °C to +70 °C (-40 °F to +158 °F) |
| Storage Temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
| Mounting | Panel or rack mount in generator control cabinet |
| Cooling | Natural convection (no forced air) |
| Enclosure | NEMA 1 / IP20 equivalent |
| Physical Size | Approx. 273.6 × 214.1 × 59.2 mm |
| Weight | Approx. 1.0–1.5 kg |
| Certifications | CE marked; UL Listed (model dependent) |
| Country of Origin | USA (some supply channels list Germany) |