Description

Description
The TRICONEX 9110 is a 16-channel digital output (DO) module engineered for the Tricon® Triple-Modular Redundant (TMR) safety instrumented system (SIS). Designed to meet the highest functional safety standards, it provides fail-safe, fault-tolerant actuation signals to critical field devices such as emergency shutdown valves, motor starters, and alarm annunciators—ensuring deterministic response during hazardous process conditions.
As a core element of Tricon’s patented TMR architecture, the 9110 continuously cross-checks outputs across three independent channels, delivering unmatched reliability for applications where failure is not an option.
Application Scenarios
At a North Sea offshore platform, a high-pressure gas compression train required a safety system capable of surviving multiple component failures without spurious trips or dangerous misses. Engineers selected the TRICONEX 9110 to drive 12 critical 24VDC solenoid valves on emergency isolation systems. During a simulated wellhead overpressure event, the 9110 executed a full shutdown in under 150 ms—well within the 200 ms safety window mandated by API RP 14C. More impressively, when a technician later induced a dual-channel fault in one 9110 module during live testing, the Tricon system maintained operation seamlessly, with zero impact on process control. This resilience prevented an estimated $ 8M in potential production loss and reinforced the platform’s “zero incident” safety record. The 9110 didn’t just respond to danger—it ensured the response would never fail.
Parameter
表格
Note: Requires external 24VDC field power supply (not provided by module); each bank must be powered separately for fault isolation.
Technical Principles and Innovative Values
Innovation Point 1: True TMR at the Output Stage – Unlike conventional redundant DO cards, the 9110 implements three physically separate output circuits per logical channel. Only when two out of three agree does the signal energize the field device—eliminating both dangerous and spurious failures per IEC 61508.
Innovation Point 2: Intelligent Field Power Supervision – The 9110 actively monitors the 24VDC field supply for each bank, detecting open wires, short circuits, or voltage drops that could prevent valve actuation—reporting faults before they compromise safety integrity.
Innovation Point 3: Seamless Integration with Tricon Logic Solvers – Output commands from the Tricon main processors are voted in hardware before reaching the 9110. ensuring that even a corrupted software command cannot trigger an unsafe action.
Innovation Point 4: Lifecycle Diagnostics via EDM Software – When paired with Triconex Enhanced Diagnostic Monitor, the 9110 provides real-time health dashboards, historical fault trends, and proof-test records—simplifying compliance with ISA S84 and reducing proof-test time by up to 50%.
Application Cases and Industry Value
During a revamp of a U.S. Gulf Coast ethylene plant’s reactor protection system, engineers replaced a legacy 1oo2 PLC with a full Tricon SIS featuring eight TRICONEX 9110 modules. The 9110 units drove 96 solenoid valves controlling quench oil injection, nitrogen purge, and reactor isolation. In the first year of operation, the system correctly initiated two emergency shutdowns due to runaway reaction temperatures. Post-event analysis confirmed all 9110 outputs responded within 120 ms, with no channel discrepancies. Equally important, during routine maintenance, EDM software identified a degraded field power fuse on one 9110 bank—allowing replacement during a planned turnaround, avoiding a potential partial-stroke test failure. The plant reported a 90% reduction in SIS-related work orders and achieved full compliance with OSHA PSM requirements. The 9110 proved that in process safety, redundancy isn’t just about uptime—it’s about guaranteed correct action.
Related Product Combination Solutions
3501: Tricon Main Processor Module—executes safety logic that drives 9110 outputs.
3664: Communication Module—reports 9110 status to DCS via Modbus or OPC.
9100: Digital Input Module—pairs with 9110 for complete SIS I/O (e.g., ESD button → 9100 → logic → 9110 → valve).
9500: Analog Output Module—complements 9110 for modulating final elements in hybrid safety loops.
Enhanced Diagnostic Monitor (EDM): Software suite for real-time health monitoring of 9110 and entire Tricon system.
Triconex Terminal Base (e.g., 8312A): Field wiring interface with removable connectors for 9110.
9111: Higher-current variant (1A/channel)—used for driving larger contactors directly.
Tricon v11 Chassis: Next-gen platform supporting hot-swap and enhanced diagnostics for 9110.
Installation, Maintenance, and Full-Cycle Support
Installing the TRICONEX 9110 requires insertion into a Tricon main chassis slot and connection to a dedicated 24VDC field power supply per output bank via the terminal base. Wiring follows strict segregation rules: safety outputs must be isolated from non-SIS circuits to maintain certification. Configuration is performed offline in Triconex Application Suite (TAS), where output tags, descriptions, and alarm thresholds are defined—then downloaded securely to the chassis.
Maintenance centers on periodic proof tests and diagnostic reviews. Using EDM, technicians can perform partial-stroke tests on valves driven by the 9110 without full process interruption. The module’s continuous self-test logs all anomalies, enabling predictive replacement before failures occur. If a unit must be swapped, hot-swap capability allows replacement during operation—critical in continuous-process facilities. Every 9110 we supply undergoes full functional validation, including TMR voting verification and field power fault simulation, ensuring it meets Triconex’s rigorous safety lifecycle requirements. Backed by an 18-month warranty and access to Schneider Electric-certified SIS engineers, we guarantee your safety outputs remain uncompromised.
Contact us for a customized solution—whether you need a single 9110 for emergency replacement or a complete Tricon SIS upgrade strategy for your next safety-critical project.