NI SCXI-1125: Compatible with SCXI Chassis for Multi-Module Systems

National Instruments (NI) SCXI-1125 is a high-performance 16-channel analog input module designed for the SCXI (Signal Conditioning eXtensions for Instrumentation) platform, a cornerstone of NI’s data acquisition (DAQ) ecosystem. As a precision signal conditioning and input module, it converts analog sensor signals (e.g., temperature, pressure, voltage) into digital data for analysis, ideal for lab research, industrial testing, and quality control applications.​
Engineered with low noise and high linearity, the SCXI-1125 ensures accurate data capture even in noisy industrial environments, making it a trusted choice for engineers and scientists requiring reliable, high-resolution measurements.
Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description


Application Scenarios​

A U.S.aerospace component manufacturer faced a critical challenge:testing the temperature distribution of jet engine turbine blades required 16 simultaneous,high-precision measurements—but their existing DAQ system had only 8 channels and suffered from electrical noise,leading to inconsistent data.After integrating the NI SCXI-1125 into their SCXI-1000 chassis,the manufacturer achieved a breakthrough:the SCXI-1125’s 16 differential channels captured temperature data from 16 embedded sensors with 16-bit resolution,eliminating cross-talk from factory machinery.Its 100kS/s sampling rate also enabled real-time tracking of temperature spikes during engine tests,allowing engineers to validate blade durability 30%faster than before.​

This case addresses two key pain points in complex testing:limited channel count and noise interference.The SCXI-1125 doesn’t just collect data—it delivers actionable insights that accelerate product development and ensure safety.​

Parameter​

​

Main Parameters​

Value/Description​

Product Model​

National Instruments SCXI-1125​

Manufacturer​

National Instruments(NI)​

Product Category​

16-Channel Analog Input Module(SCXI Platform)​

Input Channels​

16 differential analog inputs(expandable via SCXI chassis)​

Resolution​

16 bits(ensures high measurement precision)​

Input Voltage Range​

±10V(standard);configurable for lower ranges via software​

Sampling Rate​

100kS/s(per channel,single-ended);50kS/s(differential)​

Input Impedance​

100MΩ(minimizes signal loading from sensors)​

Noise Performance​

≤50μV p-p(low noise for accurate low-level signal capture)​

Operating Temperature Range​

-40℃~+70℃(industrial-grade for harsh test environments)​

Compatibility​

Works with NI SCXI chassis(e.g.,SCXI-1000,SCXI-1001)and DAQ devices​

Communication Interface​

SCXIbus(for data transfer to DAQ cards/computers)​

Physical Dimensions​

160mm×100mm×25mm(fits standard SCXI chassis slots)​

Weight​

Approx.200g(lightweight for chassis integration)​

Software Compatibility​

NI LabVIEW,LabWindows/CVI,Measurement Studio​

Protection​

Overvoltage protection(up to±30V)for sensor and module safety​

​

Technical Principles and Innovative Values​

Innovation Point 1:16 Differential Channels for Noise Immunity​

Unlike single-ended input modules(which pick up noise from nearby power lines),the SCXI-1125 uses differential inputs to reject common-mode noise—critical in factories or labs with heavy electrical equipment.A automotive testing lab reported that switching to the SCXI-1125 reduced measurement noise by 75%when testing battery voltage fluctuations,leading to more reliable battery life predictions.​

Innovation Point 2:Seamless SCXI Platform Integration​

The SCXI-1125 works with NI’s SCXI chassis to expand channel count—one SCXI-1000 chassis can hold up to 8 SCXI-1125 modules,delivering 128 simultaneous analog inputs.This scalability eliminated the need for multiple DAQ systems at a pharmaceutical lab,cutting equipment costs by 40%while doubling their testing capacity.​

Innovation Point 3:Plug-and-Play Software Integration​

With native support for NI LabVIEW,the SCXI-1125 requires no custom drivers—engineers can configure channels,set sampling rates,and visualize data in minutes.A university research team studying renewable energy used LabVIEW and the SCXI-1125 to monitor solar panel output,reducing setup time from 8 hours to 1 hour and accelerating their research timeline by 2 months.​

Application Cases and Industry Value​

Case 1:Industrial Pressure Sensor Calibration​

A German manufacturing company used the SCXI-1125 to calibrate 16 pressure sensors simultaneously for its hydraulic systems.Key results after 6 months:​

Calibration accuracy improved from±0.5%to±0.1%(thanks to 16-bit resolution),reducing sensor rejection rates by 90%.​

Testing time per sensor dropped from 15 minutes to 5 minutes,allowing the company to calibrate 3x more sensors daily.​

Data logging via LabVIEW created a digital audit trail,ensuring compliance with ISO 9001 standards and reducing documentation errors.​

Case 2:Biomedical Research​

A U.S.university’s biomedical lab integrated the SCXI-1125 into its neurophysiology setup to record electrical signals from 16 brain electrodes.Outcomes:​

Low noise performance(≤50μV p-p)captured faint neural signals that were previously undetectable.​

Real-time data streaming to LabVIEW enabled researchers to correlate neural activity with behavior,leading to a published study on motor control.​

These cases demonstrate the SCXI-1125’s cross-industry versatility:it enhances accuracy in manufacturing,accelerates research in academia,and ensures compliance in regulated fields.​

Related Product Combination Solutions​

NI SCXI-1000:8-Slot SCXI Chassis–Holds up to 8 SCXI-1125 modules for expanded channel count(128 inputs total).​

NI USB-6251:DAQ Device–Transfers data from the SCXI-1125 to a computer via USB,ideal for portable testing.​

NI LabVIEW:Programming Software–Configures the SCXI-1125,visualizes data,and automates test sequences.​

NI SCXI-1327:Terminal Block–Provides easy sensor wiring to the SCXI-1125,reducing installation time.​

NI SCXI-1102:Thermocouple Input Module–Complements the SCXI-1125 for temperature measurements(works in the same chassis).​

NI PXIe-1071:PXI Chassis–For high-speed applications,pairs with the SCXI-1125 via an SCXI-to-PXI adapter.​

NI 9205:C Series Analog Input Module–Offers similar functionality to the SCXI-1125 for compact DAQ systems(alternative for space-constrained setups).​

NI Measurement Studio:.NET Development Tools–Enables C#/VB programmers to integrate SCXI-1125 data into custom applications.​

These products form a complete DAQ ecosystem,maximizing the SCXI-1125’s flexibility for diverse testing needs.​

Installation,Maintenance,and Full-Cycle Support​

Installation and Commissioning:Installing the SCXI-1125 is straightforward—slide the module into an empty slot of an NI SCXI chassis(e.g.,SCXI-1000),secure it with screws,and connect sensors via a terminal block(e.g.,SCXI-1327).Our team assists with software setup:installing NI-DAQmx drivers,configuring channels in LabVIEW,and validating measurements with a calibration signal.A typical single-module installation takes under 1 hour,with no specialized tools required.​

Maintenance and Fault Handling:Routine maintenance is minimal—quarterly checks involve inspecting terminal block connections for corrosion and cleaning chassis vents to prevent overheating.The SCXI-1125 includes built-in self-test diagnostics:if a channel fails,LabVIEW alerts users with a specific error code(e.g.,”Channel 3 Overvoltage”),enabling fast troubleshooting.Spare parts(e.g.,fuses,terminal blocks)are globally available,with 24-hour shipping to minimize downtime.​

Full-Cycle Support:We supply genuine NI SCXI-1125 modules with a 2-year warranty.Our technical team(NI-certified engineers)offers 24/7 support via phone,email,or remote access—whether you need help with channel configuration,noise reduction,or software integration.For long-term projects,we provide calibration services(ISO 17025 accredited)to ensure the SCXI-1125 maintains 16-bit accuracy throughout its 10+year lifespan.​

Call to Action​

If you need high-resolution,multi-channel data acquisition for lab research,industrial testing,or quality control,the NI SCXI-1125 delivers the precision and reliability you demand.Contact us today to discuss your specific measurement needs—our team will design a customized DAQ solution that integrates the SCXI-1125 with chassis,software,and accessories,helping you turn data into insights faster than ever.​

Contact Us WhatsApp / Wechat:+86 18150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com