Description

Application Scenarios
In a pharmaceutical manufacturing facility’s bioreactor system,theHONEYWELL 10100-2-1provides critical pressure monitoring for sterile processes.When maintaining precise pressure levels during fermentation,the10100-2-1delivers accurate readings within±0.1%of span,ensuring optimal growth conditions for microorganisms.This precision has reduced batch variations by 30%while maintaining strict compliance with FDA regulations for process documentation.
Parameter
Main Parameters
Value/Description
Product Model
10100-2-1
Manufacturer
Honeywell
Product Type
Pressure Transmitter
Pressure Range
0-1000 psi
Accuracy
±0.1%of span
Long-term Stability
±0.1%per year
Output Signal
4-20mA HART
Supply Voltage
12-36 VDC
Process Connection
1/2″NPT
Material
316L Stainless Steel
Response Time
<100 ms
Operating Temperature
-40°C to+85°C
Media Temperature
-40°C to+125°C
Protection Rating
IP67
Certification
ATEX,IECEx,SIL 2
MTBF
>1,000,000 hours
Technical Principles and Innovative Values
Innovation Point 1:TheHONEYWELL 10100-2-1utilizes advanced silicon capacitive sensor technology that provides exceptional stability and repeatability,maintaining±0.1%accuracy even after years of continuous operation in demanding process conditions.
Innovation Point 2:Featuring built-in temperature compensation and advanced signal processing algorithms,the10100-2-1automatically corrects for environmental temperature variations,ensuring consistent performance across the entire operating temperature range from-40°C to+85°C.
Innovation Point 3:With integrated HART communication protocol,theHONEYWELL 10100-2-1enables remote configuration,calibration,and diagnostics without interrupting the process,significantly reducing maintenance time and costs while improving operational efficiency.
Application Cases and Industry Value
In a chemical processing plant handling corrosive materials,theHONEYWELL 10100-2-1demonstrated exceptional durability in measuring chlorine gas pressure.The transmitter’s 316L stainless steel construction resisted corrosion while maintaining measurement accuracy within 0.15%over three years of continuous operation.The plant’s instrumentation manager reported:”The10100-2-1transmitters have reduced our calibration frequency by 50%while providing more reliable data for our process control system.”
Related Product Combination Solutions
HONEYWELL Temperature Transmitters-Complementary temperature measurement
HONEYWELL Flow Meters-Complete flow measurement solutions
HONEYWELL Level Sensors-Tank level monitoring equipment
HONEYWELL Valve Positioners-Final control elements
HONEYWELL Process Controllers-System control units
HONEYWELL Mounting Hardware-Installation accessories
HONEYWELL Calibration Equipment-Maintenance and verification tools
Installation,Maintenance,and Full-Cycle Support
Installation preparation:Before installing theHONEYWELL 10100-2-1,verify process compatibility and ensure proper isolation valve arrangements.Use appropriate sealants and thread compounds compatible with the process media,and ensure adequate clearance for maintenance access.
Maintenance recommendations:Perform annual zero and span calibration checks using certified reference standards.The10100-2-1features built-in diagnostics that can be accessed via HART communicator,allowing for predictive maintenance scheduling and reducing unplanned downtime.
Technical support:Our instrumentation specialists provide comprehensive support from selection to commissioning and ongoing maintenance.We offer 24/7 technical assistance and can provide replacement units within 24 hours for critical applications.Contact us for a customized pressure measurement solution tailored to your specific process requirements.