Description

Application Scenarios
At a pharmaceutical manufacturing facility in Switzerland,the HE693RTD600 is used to monitor jacket temperature in multiple bioreactors during vaccine production.Each reactor requires precise temperature control within±0.5°C to ensure proper cell growth.The HE693RTD600 interfaces with Pt1000 sensors using 4-wire connections to eliminate lead resistance errors caused by 20-meter cable runs from the control panel to the reactor room.The module’s high accuracy and stability ensure consistent batch quality,and its integration with the Series 90-30 PLC allows real-time data logging and alarm triggering—meeting strict FDA 21 CFR Part 11 compliance requirements.
In a large-scale district heating plant in Scandinavia,the HE693RTD600 modules are deployed in PLC cabinets to monitor supply and return water temperatures across 12 heat exchanger stations.Installed in environments with ambient temperatures ranging from-10°C to+55°C,the modules operate continuously with no drift or calibration issues.By using 3-wire Pt100 sensors,the system achieves cost-effective yet accurate measurements.The HE693RTD600’s ability to handle multiple sensor types allows flexibility during maintenance when different RTD models are temporarily substituted,ensuring uninterrupted thermal monitoring during winter peak loads.
Parameter
Main Parameters Value/Description
Product Model HE693RTD600
Manufacturer GE Automation&Controls(formerly GE Fanuc)
Product Category Analog Input Module–RTD(Resistance Temperature Detector)
Compatible PLC GE Fanuc Series 90-30
Number of Channels 6 independent RTD inputs
Supported Sensors Pt100,Pt1000,Ni120,Balco 500,Cu10,and custom resistance sensors
Input Type 2-wire,3-wire,or 4-wire RTD configurations
Measurement Range Configurable:e.g.,-200°C to+850°C(depending on sensor)
Resolution 16-bit A/D conversion
Accuracy±0.1%of full scale(typical)
Conversion Rate~300 ms for all 6 channels
Isolation Channel-to-channel and channel-to-backplane:1500V AC
Excitation Current Low-drift,precision current source for RTD excitation
Cold Junction Compensation Built-in for reference temperature correction
Backplane Interface Connects directly to Series 90-30 I/O bus
Power Supply 5VDC from backplane
Operating Temperature 0°C to+60°C
Installation DIN-rail mount,hot-swappable design
Status Indicators RUN(green),ERROR(red),and channel-specific LEDs
Certifications CE,UL,CSA,RoHS
Technical Principles and Innovative Values
Innovation Point 1:Support for 3-wire and 4-wire RTD configurations allows users to choose between cost-effective 3-wire setups(with lead resistance compensation)or ultra-precise 4-wire Kelvin sensing,optimizing performance vs.installation cost.
Innovation Point 2:16-bit resolution and low-drift excitation circuitry ensure high accuracy and long-term stability,reducing the need for frequent recalibration in critical temperature control loops.
Innovation Point 3:Galvanic isolation(1500V AC)protects the PLC backplane from ground loops,voltage surges,and electrical noise—common in industrial environments with motors and VFDs.
Innovation Point 4:Hot-swappable design enables module replacement without powering down the PLC,minimizing downtime during maintenance or upgrades.
Innovation Point 5:Configurable sensor types via software(using CIMPLICITY or Proficy Machine Edition)provide flexibility to use different RTD standards without hardware changes,enhancing system adaptability.
Application Cases and Industry Value
A food and beverage processing plant in California uses HE693RTD600 modules to monitor pasteurization and sterilization temperatures in milk processing lines.Accurate temperature measurement is critical to meet USDA and FDA safety standards.The HE693RTD600 interfaces with Pt100 sensors in steam jackets,providing real-time feedback to the Series 90-30 PLC for closed-loop control.Over three years of operation,the modules have maintained±0.3°C accuracy,contributing to zero product recalls due to under-processing.The LED status indicators allow operators to quickly verify sensor health during line startups.
In a semiconductor cleanroom,precise ambient temperature control is essential for lithography processes.The HE693RTD600 monitors temperature in multiple zones using Pt1000 sensors with 4-wire connections to eliminate measurement errors.Its 16-bit resolution detects sub-degree fluctuations,enabling the HVAC system to maintain±0.1°C stability.The HE693RTD600’s reliability in a low-particulate environment has resulted in zero failures over five years,supporting high wafer yield rates and reducing maintenance costs.
Related Product Combination Solutions
IC693CPU311/IC693CPU350:Series 90-30 CPU–Main PLC processor that works with HE693RTD600.
IC693CHS397:10-Slot Baseplate–Mechanical rack for Series 90-30 systems.
HE693ADC300:8-Channel Analog Input Module–For 4-20mA or 0-10V signals(complements RTD inputs).
HE693CPU351:Enhanced Series 90-30 CPU–Supports larger memory and faster scan times.
IC693ACC205:Battery Backup Module–Preserves program during power loss.
IC693MDL740:Discrete Output Module–For controlling heaters,valves,or alarms based on RTD data.
IC693ALG390:Alternative RTD Module–Older model with fewer channels or lower accuracy.
Proficy Machine Edition(PME):Configuration&Programming Software–Used to set up HE693RTD600 parameters.
Installation,Maintenance,and Full-Cycle Support
The HE693RTD600 installs on DIN rail and connects directly to the Series 90-30 PLC backplane.Field wiring is made via screw terminals,supporting 3-wire and 4-wire RTD connections.Use Proficy Machine Edition(PME)or CIMPLICITY to configure the module,select sensor types,and assign I/O addresses.
Ensure proper grounding and use shielded cables to minimize noise.Terminate cable shields at the cabinet end to prevent ground loops.The RUN and ERROR LEDs provide immediate visual feedback on module status.
Routine maintenance includes checking terminal tightness,verifying sensor calibration periodically,and reviewing PLC diagnostics.The solid-state design ensures long service life with minimal failure rate.
We offer complete technical support,including wiring diagrams,configuration templates,and troubleshooting guides.Every HE693RTD600 undergoes factory calibration and electrical testing to ensure field readiness.Contact us for a full temperature monitoring solution for your process control,energy management,or industrial automation system.
选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!