Description

Application Scenarios
In a chemical processing plant’s filtration system,theH201Ci-1transmitter monitors pressure drop across filter banks to determine clogging conditions.When the differential pressure reached a critical threshold,theH201Ci-1provided accurate data that triggered an automatic backwash cycle,preventing filter damage and maintaining process efficiency.The maintenance team reported improved filter life and reduced manual monitoring requirements after installation.
Parameter
Main Parameters
Value/Description
Product Model
H201Ci-1
Manufacturer
Honeywell
Product Category
Differential Pressure Transmitter
Pressure Range
0-250 psi(Standard)
Accuracy
±0.25%of Span
Output Signal
4-20mA with HART Protocol
Power Supply
12-42VDC Loop Powered
Process Connection
1/4″NPT or 1/2″NPT
Materials
316L Stainless Steel Wetted Parts
Operating Temperature
-40°C to+85°C
Process Temperature
-40°C to+120°C
Protection Rating
IP67/NEMA 4X
Response Time
<100ms
Stability
±0.1%URL per year
Certifications
ATEX,IECEx,SIL 2/3
Technical Principles and Innovative Values
Innovation Point 1:Advanced Sensing Technology-TheH201Ci-1utilizes a high-stability capacitive sensor with temperature compensation,ensuring accurate measurements across wide operating conditions.This technology provides excellent long-term stability and minimal drift.
Innovation Point 2:Robust Construction-With 316L stainless steel wetted parts and high-protection housing,theH201Ci-1withstands harsh process conditions including corrosive media and extreme temperatures.
Innovation Point 3:Smart Communication-HART protocol compatibility enables remote configuration,calibration,and diagnostics,reducing maintenance time and improving operational efficiency.
Application Cases and Industry Value
A power plant implementedH201Ci-1transmitters for feedwater flow measurement in their boiler system.The transmitters’high accuracy and reliability contributed to a 5%improvement in combustion efficiency and reduced fuel consumption.The maintenance team reported a 40%reduction in calibration frequency compared to previous transmitters.
In a water treatment facility,H201Ci-1transmitters monitor pump differential pressure for predictive maintenance.The early detection of pump performance degradation has resulted in a 30%reduction in unplanned downtime and significant maintenance cost savings.
Related Product Combination Solutions
Honeywell HC900-Process Controller
Honeywell Experion-DCS System
Pressure Range Variants-Different Pressure Ranges
Mounting Kits-Installation Accessories
HART Communicator-Configuration Tool
Isolation Valves-Process Isolation
Impulse Lines-Pressure Connection
Signal Conditioners-Signal Processing
Installation,Maintenance,and Full-Cycle Support
Installation Preparation:Ensure proper mounting orientation and adequate support for impulse lines.Verify process compatibility and use appropriate seal materials.Follow manufacturer’s guidelines for electrical connections and grounding.
Maintenance Protocol:Perform zero and span checks during routine maintenance.Use HART communicator for remote diagnostics and configuration.Maintain records of calibration and performance data.
Technical Support Commitment:We provide comprehensive support forH201Ci-1systems,including configuration assistance,troubleshooting,and calibration services.Our instrumentation specialists offer training and documentation support.
Contact us for technical specifications and application engineering support for theH201Ci-1.Our instrumentation specialists can help you select the right pressure measurement solution for your specific process requirements.
选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!