Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | 1756-IB16ISOE |
| Manufacturer | Rockwell Automation / Allen-Bradley |
| Product Type | ControlLogix Sequence of Events Input Module |
| Input Channels | 16, individually isolated |
| Operating Voltage Range | 10…55V DC |
| Input Voltage Category | 24/48V DC sink/source |
| Isolation | 250V continuous between inputs |
| Input Current at Signal 1 | Approximately 4.5–5.1 mA |
| Backplane Current (5.1V DC) | 320 mA |
| Backplane Current (24V DC) | 2 mA |
| Timestamp Resolution | Sub-millisecond |
| Data Capture Modes | CST Per Point; FIFO (160-event buffer) |
| Removable Terminal Block | 1756-TBCH or 1756-TBSBH (36-pin) |
| Operating Temperature | 0…60 °C (32…140 °F) |
| Slot Width | 1 |
| Lifecycle Status | Active |
Main Features and Advantages
Sub-millisecond timestamping for precise event sequencing: The defining capability of the 1756-IB16ISOE is its ability to record the exact time of each input transition with sub-millisecond resolution. In CST per-point mode, the module provides two timestamps per input—one for off-to-on and one for on-to-off—allowing engineers to determine not only what happened but the precise order in which conditions changed. This transforms the 1756-IB16ISOE from a simple data acquisition device into a diagnostic instrument capable of reconstructing fault cascades that would be invisible to standard input modules.
Individually isolated inputs for flexible wiring: Each of the 16 input channels on the 1756-IB16ISOE is individually isolated, supporting sink or source wiring configurations and allowing different voltage groups to coexist within a single module. This isolation prevents ground loops and cross-channel interference, ensuring that timestamp accuracy is not compromised by electrical noise from adjacent channels or field wiring. The 250V continuous isolation rating between inputs provides robust protection in industrial environments where voltage transients are common.
Dual capture modes for different diagnostic needs: The 1756-IB16ISOE supports both CST per-point and FIFO data capture modes, giving users flexibility in how event data is retrieved and analyzed. CST mode is ideal for first-fault detection and determining the order of a sequence of transitions, with timestamps available directly in the input tag structure. FIFO mode provides a 160-point transition buffer that can be read out of the module, offering multiple transaction data for high-level fault tracing and analysis of complex event cascades. Firmware revision 2.007 and later extends timestamp support to CIP Sync format for coordinated real-time timestamping across geographically distributed systems.
WhatsApp:+86 18005022363 WeChat: +86 18005022363
Email:






