Description
The HONEYWELL FC-TSDI-16UNI is a 16-channel universal digital input module engineered for the Honeywell Safety Manager (formerly FSC – Fail Safe Control) system, a leading SIL 3-certified safety instrumented system (SIS) platform. Designed for high-integrity applications in oil & gas, chemical, power, and pharmaceutical industries, it reliably acquires binary field signals—from emergency pushbuttons and valve limit switches to flame detectors—and delivers them to the triple-modular redundant (TMR) safety logic solver with full diagnostic coverage.
Unlike standard PLC I/O, the FC-TSDI-16UNI is built to fail safely: every component, from input circuitry to voting logic, adheres to IEC 61508 and IEC 61511 standards, ensuring that dangerous failures are detected before they compromise process safety.
Application Scenarios
At a deepwater FPSO in the North Sea, a critical flare knockout drum level high-high alarm was intermittently missed due to signal bounce from long cable runs. After upgrading to the HONEYWELL FC-TSDI-16UNI, engineers enabled its built-in debounce filtering and line monitoring features. The module not only rejected transient noise but also alerted operators when a sensor wire developed high resistance—weeks before a potential failure. During an actual overfill event six months later, the FC-TSDI-16UNI transmitted the trip signal flawlessly, triggering an emergency depressurization that prevented a catastrophic release. For the safety engineer, this wasn’t just I/O—it was predictive protection.
Parameter
表格
Technical Principles and Innovative Values
Innovation Point 1: True Universal Input with Auto-Detection
The FC-TSDI-16UNI automatically adapts to field device type—whether it’s a passive switch or an active 110 V AC sensor—without jumpers or DIP switches. This simplifies spares management and reduces wiring errors during commissioning.
Innovation Point 2: Channel-Level Diagnostics with Live Monitoring
Each input continuously measures loop resistance and voltage. If a wire corrodes or a sensor fails, the module flags it as a “detected fault” and forces a safe state—long before the signal becomes unreliable.
Innovation Point 3: TMR Voting at the Module Level
In a fully redundant Safety Manager chassis, three FC-TSDI-16UNI modules operate in parallel. Their inputs are voted 2oo3 at the hardware level, eliminating single-point failures and achieving >99.999% availability.
Innovation Point 4: Hot-Swap with Zero Logic Interruption
Thanks to Honeywell’s patented synchronization protocol, the FC-TSDI-16UNI can be replaced during live operation. The safety logic continues running on the remaining two lanes while the third is serviced—critical for 24/7 plants.
Application Cases and Industry Value
A liquefied natural gas (LNG) train in Qatar uses FC-TSDI-16UNI modules to monitor compressor seal leakage, turbine overspeed, and fire/gas detection signals. During a scheduled proof test, the system identified a degraded solenoid coil on a shutdown valve via abnormal current draw—allowing replacement during planned downtime. Over five years, the facility achieved zero spurious trips and 100% demand success rate, directly attributable to the diagnostic depth of the FC-TSDI-16UNI.
In a U.S. ethylene cracker, legacy relay-based shutdown logic was replaced with a Safety Manager system featuring FC-TSDI-16UNI cards. The result? A 40% reduction in SIF (Safety Instrumented Function) proof test time and full compliance with OSHA PSM and EPA RMP regulations—turning safety from a cost center into a competitive advantage.
Related Product Combination Solutions
FC-TB-DI-16: Dedicated terminal base with screw terminals and fuse protection for FC-TSDI-16UNI
FC-TSDO-16: 16-channel safety digital output module – pairs with FC-TSDI-16UNI for complete SIF loops
FC-TSAI-8: 8-channel analog input module – for pressure, temperature, or level in safety functions
Safety Manager Controller (e.g., FC-SCM-01): TMR logic solver that processes inputs from FC-TSDI-16UNI
Experion Safety Builder: Configuration software – used to assign tags, set filters, and validate diagnostics
FC-PWR-24: Redundant 24 V DC power supply – ensures continuous operation of FC-TSDI-16UNI
FC-RACK-8: Safety I/O chassis – supports up to 8 modules including FC-TSDI-16UNI
NAMUR Isolators (e.g., MTL/Pepperl+Fuchs): For intrinsically safe interfaces in hazardous areas
Installation, Maintenance, and Full-Cycle Support
Installing the HONEYWELL FC-TSDI-16UNI begins with mounting the FC-TB-DI-16 terminal base on a DIN rail and wiring field devices using 14–22 AWG conductors. The module then snaps securely onto the base—no tools required. For hazardous areas, ensure proper intrinsic safety barriers are installed upstream.
During commissioning, use Experion Safety Builder to configure input type (dry/wet/NAMUR), debounce time, and alarm thresholds. Built-in loop test functions allow validation without physical actuation of field devices—reducing risk during startup.
Maintenance is predictive: the dual LEDs provide instant status, while the Safety Manager logs all diagnostic events. If a channel faults, replace the module in minutes—even online in redundant systems. No recalibration is ever needed; the FC-TSDI-16UNI is solid-state and drift-free.
We supply only genuine FC-TSDI-16UNI modules—either new from Honeywell distribution or factory-refurbished with full functional testing, including SIL compliance verification and LED diagnostics. Each unit includes a certificate of conformance and compatibility assurance for your Safety Manager revision. Our team offers configuration templates, SIL verification support, and 24/7 technical assistance from certified Safety Manager engineers.
WhatsApp:+86 18150087953 WeChat: +86 18150087953