Emerson Rosemount A6370D 4–20 mA HART Transmitter Compatible with RTD, Thermocouple & Ohms Inputs

The Emerson A6370D is a model designation within Emerson’s Rosemount 644 family of high-performance, loop-powered temperature transmitters. Designed for precise and reliable measurement of temperature using RTDs (e.g., Pt100), thermocouples (Types J, K, T, etc.), or resistance inputs, the A6370D delivers a standardized 4–20 mA analog output with embedded HART® digital communication. It supports both head-mounted (in sensor head) and remote DIN-rail mounted configurations, making it ideal for demanding applications in oil & gas, chemical processing, power generation, and pharmaceutical manufacturing—especially where safety integrity (SIL 2/3 per IEC 61508) and hazardous area compliance (ATEX, IECEx, FM) are required.

Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description


Application Scenarios

At a European biopharmaceutical plant, inconsistent batch temperatures during fermentation were causing yield variability. Legacy bimetallic sensors lacked precision and diagnostics. Engineers replaced them with Emerson A6370D transmitters paired with Pt100 RTDs, mounted remotely on DIN rails near control panels. The A6370D’s ±0.1°C accuracy and real-time HART diagnostics enabled operators to detect early sensor drift—preventing a potential $ 2M batch loss. Integration with the plant’s AMS Device Manager allowed predictive calibration scheduling, reducing maintenance visits by 60%. In this sterile, highly regulated environment, the Emerson A6370D became a cornerstone of process consistency and data integrity.

Parameter

表格

Technical Principles and Innovative Values

Innovation Point 1: Advanced Sensor Diagnostics with Early Fault Detection

The Emerson A6370D continuously monitors sensor health—detecting open circuits, short circuits, and gradual drift—before they cause process excursions. This enables true predictive maintenance.

Innovation Point 2: Dual-Sensor Input with Automatic Switchover (Optional)

Certain A6370D configurations support primary/backup RTD inputs, automatically switching to the secondary sensor upon failure—critical for continuous processes like distillation or sterilization.

Innovation Point 3: SIL-Certified Architecture for Functional Safety

With built-in self-diagnostics (coverage >90%) and certified hardware/software design, the A6370D meets requirements for use in Safety Instrumented Functions (SIFs) up to SIL 3.

Innovation Point 4: Seamless Asset Management Integration

Via HART over existing 4–20 mA wiring, the A6370D delivers device status, calibration history, and process variables to AMS Suite—reducing manual rounds and improving data traceability.

Application Cases and Industry Value

In a Middle Eastern LNG facility, cryogenic temperature monitoring on boil-off gas lines required extreme reliability at –160°C. The Emerson A6370D, configured for 4-wire Pt100 with enhanced cold-end compensation, provided stable readings where competitors’ transmitters drifted. Its SIL 2 rating also satisfied the site’s SIS requirements for high-level shutdown interlocks. Over three years, zero transmitter-related trips were recorded.

Similarly, a U.S. municipal water treatment plant used the A6370D to monitor digester temperatures in explosive (Class I, Div 1) zones. The ATEX/FM approvals and intrinsically safe design eliminated the need for bulky isolators—simplifying installation while ensuring compliance.

Related Product Combination Solutions

Rosemount 6888 or 3144P: Higher-end wireless or Foundation Fieldbus alternatives for advanced networks

Rosemount 644 Head-Mount Version (e.g., A6360D): For direct sensor-head installation

AMS Device Manager: Software platform for configuring, calibrating, and diagnosing A6370D transmitters

Rosemount 475 Field Communicator: Handheld tool for on-site HART configuration

Pt100 RTD Sensors (e.g., Rosemount 68 series): High-stability temperature elements optimized for A6370D

DIN Rail Mounting Kit (e.g., 00644-9001): Standard accessory for remote A6370D installation

Loop Isolators / Barriers (e.g., MTL, Pepperl+Fuchs): Required for intrinsic safety in hazardous areas

DeltaV or Ovation DCS: Emerson control systems with native HART integration for A6370D data

Installation, Maintenance, and Full-Cycle Support

The Emerson A6370D is designed for rapid deployment: mount on standard 35 mm DIN rail, connect two wires for power/output, and attach sensor leads. Configuration is done remotely via HART—no need to open the housing in hazardous zones. Optional local display modules provide on-device visibility of process values and status.

We rigorously test every A6370D unit for loop functionality, HART communication integrity, input accuracy across temperature ranges, and compliance with specified certifications (e.g., ATEX, SIL). Each unit undergoes burn-in and calibration verification before shipment.

All transmitters come with a 24-month warranty, full documentation (including EU Declarations of Conformity), and optional accredited calibration certificates (ISO 17025). Our technical team provides support for:

HART configuration templates

SIL validation documentation

Migration from legacy transmitters (e.g., Moore Industries, Yokogawa)

Integration with asset management or cloud platforms

Contact us for a verified Emerson A6370D solution—whether you’re designing a new skid, upgrading a legacy temperature loop, or securing certified spares for critical infrastructure.

Contact Us WhatsApp / Wechat:+86 18150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com