Description
The F7130A 984713060 is a 16-channel digital input module developed by HIMA Paul Hildebrandt GmbH,a global leader in functional safety systems.Designed for use in HIMA’s HIMax,H41q,and H51q safety instrumented systems(SIS),this module provides high-integrity signal acquisition from field devices such as emergency pushbuttons,limit switches,and fire/gas detectors.Built to meet IEC 61508 SIL 3 requirements,the F7130A 984713060 combines fault-tolerant architecture,continuous self-diagnostics,and robust electrical isolation to ensure reliable operation in the most demanding safety-critical applications.
Engineered for zero compromise on safety,the F7130A 984713060 delivers deterministic response,comprehensive diagnostics,and seamless integration into certified safety control architectures.
Application Scenarios
At a major LNG export terminal in the Middle East,a facility-wide upgrade of its Emergency Shutdown(ESD)system required replacing legacy non-certified I/O with fully SIL 3-compliant hardware.Engineers selected the F7130A 984713060 to interface over 200 field-initiated shutdown signals—from rupture disc sensors to manual trip stations—into the new HIMA H51q safety controllers.During commissioning,the module’s built-in short-circuit detection instantly flagged a miswired solenoid valve loop,preventing a potential undetected fault that could have compromised system integrity.Over two years of operation,the F7130A 984713060 has maintained 100%diagnostic coverage with zero spurious trips,even during sandstorms and ambient temperatures exceeding 50°C.For the safety team,it became the“silent guardian”of plant integrity—always watching,always ready.
This real-world resilience underscores why the F7130A 984713060 is trusted where human lives and environmental protection depend on flawless signal interpretation.
Parameter
Main Parameters Value/Description
Product Model F7130A 984713060
Manufacturer HIMA Paul Hildebrandt GmbH
Product Category SIL 3 Digital Input Module(Safety I/O)
Number of Channels 16 isolated digital inputs
Input Voltage 24 VDC(nominal),compatible with dry contacts and powered sources
Input Type Compatible with NAMUR sensors,mechanical contacts,and solid-state switches
Diagnostic Coverage>99%(per IEC 61508),including wire break,short circuit,and cross-wiring detection
Isolation Channel-to-channel and channel-to-backplane galvanic isolation(≥500 VAC)
Certifications IEC 61508 SIL 3,IEC 61511,EN 5012x(Rail),ATEX(optional for hazardous areas)
Redundancy Support Fully supports 1oo2,2oo3 voting in HIMA redundant controller racks
Hot-Swap Capable Yes–modules can be replaced during system operation without shutdown
Operating Temperature-25°C to+70°C(industrial extended range)
Mechanical Form Factor Standard HIMA I/O carrier-compatible;plug-in design with coded keying
Technical Principles and Innovative Values
Innovation Point 1:Continuous Online Diagnostics–Unlike conventional I/O,the F7130A 984713060 performs real-time health checks on every channel using pulsed test currents and impedance monitoring,detecting faults like open wires or shorted sensors before they cause safety function failure.
Innovation Point 2:True 24 VDC Signal Integrity–The module uses dual-supervision circuitry to distinguish between valid 24 VDC signals,floating wires,and grounded faults—eliminating false triggers common in noisy industrial environments.
Innovation Point 3:Seamless Redundancy Integration–In HIMA’s 2oo3(two-out-of-three)architecture,three F7130A 984713060 modules operate in parallel,with voting logic ensuring safety even if one module fails—critical for uninterrupted operation in refineries or power plants.
Innovation Point 4:Future-Proof Maintenance–With hot-swap support and LED status per channel(green=OK,red=fault),technicians can replace a faulty F7130A 984713060 in under 5 minutes without halting production—a game-changer for continuous-process industries.
Application Cases and Industry Value
In a European pharmaceutical plant producing sterile injectables,regulatory auditors mandated full SIL 2 compliance for all reactor interlocks.The facility deployed F7130A 984713060 modules to monitor door interlocks,pressure relief valves,and temperature limits on critical bioreactors.The modules’diagnostic logs provided auditable proof of system health,satisfying FDA 21 CFR Part 11 requirements.More importantly,during a steam-in-place(SIP)cycle,a failing pressure switch was detected via wire-break diagnostics—preventing an unsafe batch release.The plant avoided a$2M product recall and passed its next audit with zero findings.
Similarly,in a high-speed rail signaling project,the F7130A 984713060 interfaces trackside emergency stop buttons into a HIMA H41q controller.Its immunity to electromagnetic interference from overhead catenaries ensured no nuisance trips—even during lightning strikes—making it a cornerstone of passenger safety.
Related Product Combination Solutions
F7131A:16-channel digital output module—pairs with F7130A 984713060 for complete safety loops(sense+actuate).
F7140A:Analog input module for 4–20 mA safety signals—ideal for pressure/temperature shutdown thresholds.
H51q CPU:Central processing unit for HIMax SIS—designed to host multiple F7130A 984713060 modules in redundant configurations.
F7010:Power supply module for HIMA I/O carriers—ensures clean,redundant power to F7130A units.
HIMA HIQuad X:Next-gen safety platform—backward-compatible with F7130A 984713060 for phased migration.
F7001 Carrier Base:Mechanical and electrical base for mounting F7130A 984713060 in standard HIMA racks.
HIMA SafeLink:Remote I/O solution—extends F7130A functionality to distant skids via fiber optic links.
F7190:Communication module for PROFIsafe or Modbus/TCP—enables integration of F7130A data into DCS or asset management systems.
Installation,Maintenance,and Full-Cycle Support
Installing the F7130A 984713060 begins with securing it into a HIMA-approved I/O carrier(e.g.,F7001)within a certified safety rack.Field wiring connects to clearly labeled spring-clamp terminals,with optional shield connections for EMI-prone areas.No DIP switches or jumpers are needed—the module auto-configures based on backplane communication with the HIMA controller.Commissioning is streamlined via HIMA’s ESuite engineering software,which validates channel assignments and diagnostic thresholds.
For maintenance,each F7130A 984713060 features per-channel LEDs and detailed fault codes accessible through the safety controller’s HMI.If replacement is required,the hot-swap design allows removal while the system remains online—critical for 24/7 operations.We recommend annual verification of diagnostic coverage using HIMA’s test procedures,but the module’s solid-state design ensures minimal wear over decades of service.
Every F7130A 984713060 we supply is factory-tested against HIMA’s original specifications,including full functional validation under thermal stress.Units include traceable calibration records and are backed by a 24-month warranty.Our certified HIMA engineers provide lifetime technical support—from wiring diagrams to SIL verification documentation.Contact us for a customized solution and secure your safety-critical infrastructure with confidence.
选择深圳长欣,选择放心,售后无忧 大量现货,当天顺丰发货!!!


WhatsApp:+86 18150087953 WeChat: +86 18150087953
Email: