ICS Triplex T8271 Fan Tray with 24 Vdc Operation – Ideal for Harsh Industrial Environments

The ICS Triplex T8271 is a specialized fan tray designed for roof – mounted installations in industrial settings. It plays a crucial role in maintaining optimal environmental conditions within cabinets housing Trusted systems. Engineered with precision, the T8271 is tasked with efficiently exhausting air from the cabinet, which helps in regulating the internal temperature and preventing overheating of sensitive electronic components.

Category:
Contact Us WhatsApp / Wechat:+8618150087953 / +86 18005022138
Phone:+86 18150087953 / +86 18005022138
Email:sales@cxplcmro.com

Description

Product Overview​

The ICS Triplex T8271 is a specialized fan tray designed for roof-mounted installations in industrial settings.It plays a crucial role in maintaining optimal environmental conditions within cabinets housing Trusted systems.Engineered with precision,the T8271 is tasked with efficiently exhausting air from the cabinet,which helps in regulating the internal temperature and preventing overheating of sensitive electronic components.​

This fan tray is designed to be a reliable and integral part of the overall system infrastructure.By ensuring proper ventilation,it contributes to the extended lifespan and stable operation of the equipment within the cabinet.Whether it’s in an oil and gas plant,a chemical processing facility,or a power generation station,the T8271 can be counted on to provide consistent air exhaust performance.It is typically installed one per cabinet bay,making it a standardized solution for maintaining air quality and temperature control in multi-bay cabinet setups.​

Technical Specifications​

Parameter Name​

Parameter Value​

Product Model​

ICS Triplex T8271​

Manufacturer​

ICS Triplex​

Product Type​

Fan Tray​

Mounting Type​

Roof-Mounted​

Voltage​

24 Vdc(operational range:18 Vdc-28 Vdc)​

Fan Type​

Equipped with 8 Papst type 8414 NG fans​

Fan Reliability(MTBF)​

At 40°C:70,000 hours;At 70°C:35,000 hours​

Fusing​

Internal 500 mA anti-surge fuse​

Power Consumption​

2 x 8 W​

Air Flow(at 3100 rpm)​

69 m³/h(40.6 ft³/min)​

Operating Temperature​

0°C to+60°C(+32°F to+140°F)​

Non-operating Temperature​

-20°C to+70°C(-4°F to+158°F)​

Relative Humidity​

10%to 95%,non-condensing​

Dimensions(Height x Width x Depth)​

88 mm(3.46 in)x 483 mm(19 in)x 225 mm(8.86 in)​

Weight​

2.9 kg(6.39 lb)​

Protection Rating​

Meets IP20 rating with roof cowl fitted​

Main Features and Advantages​

High-Performance Fans​

The T8271 comes equipped with 8 Papst type 8414 NG fans,which are known for their reliability and efficient performance.These fans are capable of moving a significant volume of air,with an air flow rate of 69 m³/h(40.6 ft³/min)at 3100 rpm.This high-volume air movement ensures effective heat dissipation from the cabinet,keeping the internal components at a safe operating temperature.The fans also have an impressive mean time between failures(MTBF).At 40°C,the MTBF is 70,000 hours,and at 70°C,it is 35,000 hours.This long-lasting performance reduces the frequency of maintenance and replacement,resulting in lower operational costs.​

Low Noise Operation​

Each individual fan on the T8271 operates at a relatively low noise level of 32 dB.When all the fans are running together,the combined noise level is 41 dB.In industrial environments where noise pollution can be a concern,especially in areas where operators are present or in facilities with noise-sensitive equipment,this low-noise operation is a significant advantage.It allows for a quieter working environment without sacrificing the fan tray’s performance in terms of air circulation and heat removal.​

Protection and Safety Features​

The fan tray has an internal 500 mA anti-surge fuse.This fuse acts as a safeguard against electrical surges that could potentially damage the fans or other components within the fan tray.In industrial settings,electrical disturbances are common,and the anti-surge fuse helps protect the integrity of the T8271 and ensures its continuous operation.Additionally,with the roof cowl fitted,the T8271 meets the IP20 protection rating.This means it is protected against solid objects larger than 12 mm(such as fingers)and provides a basic level of protection against dust,which is important for maintaining the performance and lifespan of the fans in industrial environments with airborne particles.​

Wide Operating Temperature Range​

The T8271 is designed to operate within a temperature range of 0°C to+60°C(+32°F to+140°F)and can withstand non-operating temperatures from-20°C to+70°C(-4°F to+158°F).This wide temperature tolerance makes it suitable for use in various industrial locations,regardless of the local climate conditions.Whether it’s a hot and humid environment in a tropical region or a cold and dry area in a high-altitude industrial site,the T8271 can function reliably,ensuring consistent ventilation and temperature control for the cabinet-housed equipment.​

Application Field​

Oil and Gas Industry​

In oil and gas plants,there are numerous cabinets housing control systems,PLCs,and other critical electronic equipment.These components generate heat during operation,and overheating can lead to system failures,which could have serious consequences for production and safety.The ICS Triplex T8271 is installed on the roofs of these cabinets to exhaust the hot air,maintaining a stable internal temperature.For example,in a gas processing plant,the control cabinets for the gas compression units are equipped with T8271 fan trays.The efficient air circulation provided by the fan trays helps prevent overheating of the control electronics,ensuring uninterrupted operation of the compression process.​

Chemical Processing​

Chemical plants often have a large number of control systems and instrumentation cabinets.These cabinets are exposed to a variety of environmental factors,including chemical fumes and temperature fluctuations.The T8271 is used to ventilate these cabinets,removing the hot air and any potentially harmful fumes that may have entered.In a chemical reactor control room,the cabinets housing the control systems for the reactor’s operation are fitted with T8271 fan trays.The fan trays not only keep the components cool but also help in preventing the accumulation of chemical vapors that could corrode or damage the sensitive electronics.​

Power Generation​

Power generation stations,whether they are coal-fired,gas-fired,or nuclear,have extensive control systems and monitoring equipment housed in cabinets.These cabinets need to be properly ventilated to ensure the reliable operation of the equipment.The T8271 is installed on the roofs of these cabinets to provide the necessary air exhaust.In a coal-fired power plant,the control cabinets for the boiler and turbine systems use T8271 fan trays.By maintaining a proper temperature within the cabinets,the fan trays contribute to the stable operation of the power generation process,reducing the risk of equipment failures and power outages.​

Related Products​

ICS Triplex Cabinet Systems:The T8271 is specifically designed to be installed on the roofs of cabinets within ICS Triplex’s cabinet systems.These cabinets house various components of the Trusted systems,and the T8271 fan tray is an essential part of the overall cabinet ventilation solution.The cabinets are engineered to be robust and suitable for industrial environments,and the T8271 complements their design by providing efficient air exhaust.​

Power Supplies for ICS Triplex Systems:A reliable power supply is crucial for the operation of the T8271.Power supplies such as the ICS Triplex PS2400,which provides 24V DC redundant power,can be used to power the T8271.The stable power supply ensures that the fan tray operates continuously and without interruption,even in the event of a power failure in one of the power sources.​

Temperature Monitoring Sensors:To effectively manage the temperature within the cabinets,temperature monitoring sensors can be used in conjunction with the T8271.These sensors can be installed inside the cabinet to measure the temperature.If the temperature exceeds a certain threshold,the T8271 can be adjusted to increase the air flow rate,or additional cooling measures can be implemented.This combination of sensors and the fan tray provides a more comprehensive temperature control solution.​

Air Filters:In industrial environments with high levels of dust or particulate matter,air filters can be installed in the intake or exhaust ducts of the T8271 fan tray.These filters help in preventing the entry of dust into the cabinet,which can accumulate on the components and affect their performance.By using air filters,the lifespan of the equipment within the cabinet and the T8271 itself can be extended.​

Installation and Maintenance​

Installation​

Before installing the ICS Triplex T8271,carefully inspect the fan tray for any physical damage.Check for bent fan blades,loose connections,or any signs of wear.Ensure that the roof-mounting location on the cabinet is clean and free from any obstructions.The T8271 has a relatively compact design with dimensions of 88 mm(height)x 483 mm(width)x 225 mm(depth),which facilitates easy installation.Follow the provided installation instructions carefully to securely mount the fan tray on the cabinet roof.Connect the 24V DC power supply,ensuring that the voltage is within the specified range of 18 Vdc-28 Vdc.Once installed,perform a quick test to ensure that the fans are running smoothly and that the air flow is as expected.​

Maintenance​

Regular maintenance of the T8271 is essential to ensure its continued performance.Periodically check the fans for any signs of abnormal noise or reduced air flow.If a fan is not operating correctly,it may be due to a damaged blade,a worn-out bearing,or an electrical issue.Replace the faulty fan as soon as possible.Check the internal 500 mA anti-surge fuse regularly.If the fuse has blown,identify and rectify the cause of the electrical surge before replacing the fuse.Clean the fan tray and the roof-mounting area periodically to remove any dust or debris that may have accumulated.This helps in maintaining the efficiency of the air flow and prevents the blockage of the fan vents.Keep a record of the maintenance activities and the performance of the T8271 over time to detect any trends or potential issues early.​

Product Guarantee​

We offer 100%factory-original ICS Triplex T8271 fan trays,accompanied by a manufacturer’s certificate of authenticity.All units come with a 12-month quality guarantee.In the unlikely event that the T8271 fails due to material or manufacturing defects(excluding damage caused by improper installation or misuse),we provide a free replacement.Our technical support team is available to assist with any installation,configuration,or troubleshooting queries related to the T8271.We are committed to ensuring that our customers receive a reliable and high-performing product,backed by excellent after-sales service.Trust in the ICS Triplex T8271 for your industrial cabinet ventilation needs.​

Contact Us WhatsApp / Wechat:+86 18150087953 / +86 18005022138
Phone:+86 18150087953 / +86 18005022138
Email:sales@cxplcmro.com