Description

Key Applications
At a large combined-cycle power plant in Asia,the turbine control system(TCS)from a third-party vendor used PROFIBUS DP for I/O communication,while the main DCS was based on ABB’s Symphony platform.
To integrate TCS status signals(bearing vibration,speed,valve positions)into the central DCS for monitoring and alarm handling,engineers installed the ABB SINT4330C 3BSE020811R1 in the DCS I/O rack.The module was configured as a DP slave connected to the TCS’s PROFIBUS network.
Within hours of commissioning,all critical turbine parameters were visible in the DCS HMI,enabling operators to view integrated plant-wide data on a single screen.The SINT4330C ensured deterministic,low-latency communication with less than 10ms cycle time,meeting the plant’s operational requirements.
This deployment eliminated the need for hardwired analog/digital signals,reducing cabling costs and improving system flexibility.
Technical Parameters
Parameter Specification
Model Number SINT4330C 3BSE020811R1
Manufacturer ABB
Function PROFIBUS DP Slave Interface
Protocol PROFIBUS DP(according to IEC 61158/61784)
Baud Rate 9.6 kbps to 12 Mbps(auto-detection)
Max Devices per Segment Up to 126 slaves(depending on network design)
Interface RS-485(9-pin D-sub or terminal block)
Topology Support Linear,bus,or star(with repeaters)
Redundancy Support Yes–dual-port for redundant networks
Power Supply 24 VDC via backplane(OCS rack)
Installation DIN rail mount(35mm),fits SDCS I/O racks
Operating Temperature 0°C to 55°C
Status Indicators PWR(Power),RUN(Running),COM(Communication),ERR(Error)
Compliance CE,UL,CSA,ATEX(industrial standards)
Technical Principles&Innovation Highlights
1.Seamless System Integration
The SINT4330C allows ABB DCS systems to communicate with non-ABB devices using the widely adopted PROFIBUS DP standard—eliminating data silos and enabling unified control strategies.
2.High Availability with Redundancy
Supports redundant PROFIBUS networks(e.g.,via SINT4330C dual units),ensuring continuous communication even if one network segment fails—critical for safety and process continuity.
3.Plug-and-Play Configuration
Configured via ABB’s engineering tools(e.g.,Control Builder M),the module integrates easily into the DCS I/O structure.Device profiles(GSD files)can be imported for fast setup.
4.Real-Time Performance
Guarantees deterministic data exchange with cycle times suitable for process control(typically 1–50 ms),ensuring timely updates of field data.
5.Robust Industrial Design
Built for 24/7 operation in harsh environments with EMI resistance,wide temperature tolerance,and secure DIN-rail mounting.
Application Cases&Industry Value
Oil Refinery(Middle East):Used SINT4330C to connect ABB DCS with Siemens S7-400 PLCs controlling pump stations.Achieved full remote monitoring and reduced interface errors by 70%.
Water Treatment Plant(Europe):Integrated multiple wastewater lift stations using PROFIBUS-connected RTUs.The SINT4330C enabled centralized control without additional I/O cards or cabling.
Steel Mill(China):Connected rolling mill drives(ABB ACS800 series)to the DCS via PROFIBUS.Enabled real-time speed,torque,and fault status monitoring in the main control room.
These cases demonstrate how the SINT4330C reduces integration complexity,lowers engineering costs,and enhances operational visibility.
Related Product Combination Solutions
Product Model Purpose
SDCSCON3 3BSE018354R1 CPU module that communicates with SINT4330C via backplane
SINT4330C 3BSE020811R1 PROFIBUS DP slave interface
PROFIBUS Repeater Siemens RS485 Repeater Extends network length and segment capacity
GSD File Manager ABB PCM600/Control Builder M For importing device profiles and configuring the network
PROFIBUS Cable ABB or Siemens 6XV1830-XXX Standard purple PROFIBUS trunk cable
Termination Resistors 220ΩRequired at both ends of the bus segment
Redundant Power Supply SF810 3BSE018501R1 Ensures continuous power to the communication rack
Installation,Maintenance&Support
Installation Steps:
Mount the SINT4330C on a 35mm DIN rail in an SDCS I/O rack.
Connect to the OCS backplane for power and internal communication.
Wire the PROFIBUS RS-485 interface using twisted-pair shielded cable.
Terminate both ends of the bus with 220Ωresistors.
Configure via Control Builder M using GSD files from connected devices.
Maintenance Tips:
Check LED status regularly(PWR,RUN,COM,ERR).
Inspect cable connections and shielding integrity.
Monitor bus error counters in the DCS diagnostics.
Replace if communication failures persist after troubleshooting.
Full-Cycle Support:
We offer technical documentation,configuration support,GSD file assistance,and retrofit planning for legacy ABB DCS systems using the SINT4330C.
Whether you’re integrating a new drive system or replacing a failed module,the ABB SINT4330C 3BSE020811R1 delivers reliable,standards-based communication for industrial automation.