Description

🔧Key Functions&Role in the System
The DS200DCFBG1BNC plays a critical role in generator excitation control and reliability:
Monitors DC Field Power Supply:
Tracks voltage and current from the exciter(which supplies DC to the generator rotor).
Ensures stable field current for proper generator voltage and reactive power control.
Battery Backup Interface:
Connects to DC battery banks that provide backup power to the excitation system during AC power loss.
Enables black-start capability or smooth transition during grid disturbances.
Fault Detection&Diagnostics:
Detects under-voltage,over-voltage,charger failure,or battery degradation.
Sends alarm/status signals to the Mark VIe controller(via RTB or TBC interface).
Redundancy Management:
Works in redundant pairs(A&B channels)to ensure high availability.
Supports hot-swap replacement.
Communication with Controller:
Interfaces with the TBC(Turbine Board Controller)or RTB(Remote Terminal Board)via backplane.
Provides real-time data to the HMI(Sohio or Proficy)for operator visibility.
📌Technical Highlights
Parameter Specification
System GE Mark VI/Mark VIe Turbine Control
Voltage Monitoring 125 VDC or 250 VDC systems
Signal Types Analog(voltage/current),Digital(status,alarms)
Connectors Spring clamp or screw terminals(not actual BNC)
Backplane Interface VMEbus or Ethernet-based(depending on tray)
Redundant Yes–typically used in dual-tray configurations
Hot-Swappable Yes
Diagnostics LED indicators for power,comms,fault
Firmware Configurable via TCT(Turbine Configuration Tool)or Mark VIe Console
🏭Typical Applications
Gas Turbines:LM2500,6FA,7EA,9FA
Steam Turbines:In combined-cycle power plants
Power Plants:Simple cycle,combined cycle,cogeneration
Oil&Gas:Offshore platforms,LNG plants,compressor stations
Black Start Units:Where battery-backed excitation is critical
🔗Related Components in Mark VI/VIe System
Part Number Function
DS200TBCxGx Turbine Board Controller(main CPU)
DS200REGxGx Regulator Board(excitation control)
DS200PSDxGx Power Supply Board
DS200RTBxGx Remote Terminal Board(I/O interface)
DS200DCCxGx DC Charger Control Board
TCT Software Configuration&diagnostics tool
Sohio/Proficy HMI Operator interface
🛠️Installation&Maintenance Tips
Handle with ESD Protection:Always use a grounded wrist strap.
Verify Redundancy:Before removing,ensure the other channel is healthy.
Check Firmware Version:Match firmware across redundant boards.
Monitor Alarms:Use TCT or HMI to check for”DC Field Loss”,”Charger Fail”,or”Battery Weak”.
Terminal Torque:Ensure proper tightening of screw terminals(typically 0.5–0.6 Nm).
Label Wiring:Before removal,label all field connections.
❗Obsolescence&Availability
The DS200 series is part of the Mark VI system,which is being phased out in favor of Mark VIe(Ethernet-based)and Mark VII.
However,DS200DCFBG1BNC is still in active use in many plants.
Available through:
GE Digital Field Service
Certified Third-Party Suppliers
Refurbished/Remanufactured Units(with warranty)
✅Product Guarantee(For Suppliers)
When sourcing DS200DCFBG1BNC:
Test for power-on functionality
Verify I/O signal integrity
Clean and inspect for corrosion
Provide 12–24 month warranty
Include test report and burn-in data
Offer technical support for integration
📎Need More?
If you need any of the following,I can help:
✅Datasheet or manual PDF
✅Pinout or wiring diagram
✅Replacement or upgrade path(e.g.,to Mark VIe)
✅Troubleshooting guide(e.g.,”Field Loss”alarm)
✅How to test with TCT software
ABB 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 3BHE031197R0001 3BHB030310R0001 In stock!!! Interested parties please inquire