Description

Description:
The BENTLY NEVADA 125760-01 is a high-precision proximitor/preprocessor module manufactured by BENTLY NEVADA,a global leader in rotating machinery condition monitoring solutions.As a core component of industrial vibration monitoring systems,it processes raw signals from eddy-current sensors(e.g.,BENTLY 330180)to convert mechanical vibration,axial position,and speed data into standardized 4-20mA analog outputs—enabling real-time status tracking of critical rotating equipment.
This industrial-grade module features ultra-low measurement drift,built-in sensor fault detection,and wide environmental adaptability,making it indispensable for power plants,oil refineries,and mining operations.It seamlessly integrates with BENTLY’s 3500/2000 monitoring systems,providing early warning of equipment faults(e.g.,bearing wear,rotor imbalance)to prevent catastrophic failures and unplanned downtime.
Application Scenarios:
A 1,200MW coal-fired power plant in China faced recurring issues with its steam turbine vibration monitoring:the old preprocessor modules had inconsistent signal conversion(measurement error up to±5%),leading to 2 false alarms and 1 missed rotor imbalance fault in 1 year—resulting in a 3-day turbine overhaul costing~
800,000.Afterupgradingto∗∗BENTLYNEVADA125760−01∗∗modules(pairedwithBENTLY330180eddy−currentsensors),theplantachieveddramaticimprovements:themodule’s±0.1
650,000,and eliminated false alarms entirely.This case highlights how BENTLY NEVADA 125760-01 solves core pain points—measurement inaccuracy and lack of fault visibility—for critical rotating machinery.
Parameter:
Main Parameters
Value/Description
Product Model
BENTLY NEVADA 125760-01
Manufacturer
BENTLY NEVADA(Global leader in rotating machinery condition monitoring)
Product Category
Proximitor/Preprocessor Module(for vibration&position monitoring)
Input Type
Eddy-current sensor signals(compatible with BENTLY 3301/3500 series sensors)
Measurement Range
Vibration:0–500μm peak-to-peak;Axial position:0–20 mm
Output Signal
2×4-20mA analog outputs(1 for vibration,1 for position/speed)–industry-standard for DCS integration
Measurement Accuracy
±0.1%of full scale(at 25°C)–ensures reliable fault detection
Operating Voltage
24V DC(±15%tolerance;supports industrial power fluctuations)
Operating Current
0.3A Max(at 24V DC;low power for cabinet integration)
Protection Features
Sensor short-circuit protection;Overvoltage protection(≤36V DC);Reverse polarity protection
Operating Temperature
-40°C to+70°C(wide range for harsh industrial environments)
Environmental Ratings
Relative humidity:5%–95%(non-condensing);Protection class:IP20(rack-mounted)
Physical Dimensions
100mm×80mm×30mm(L×W×D;fits BENTLY 3500 system racks)
Weight
~0.2kg(lightweight for easy rack installation)
Compatibility
BENTLY 3500 Monitoring System,BENTLY 2000 Series,ABB 800xA DCS,Rockwell ControlLogix
Certifications
CE,UL,CSA;ATEX(Ex d IIC T6 Gb)–suitable for explosive zones(e.g.,oil refinery Zone 2)
Response Time
≤10ms(real-time signal processing for fast fault detection)
Diagnostic Features
Sensor fault detection(open/short circuit);Module self-test;Fault status LED indicator
Technical Principles and Innovative Values:
Innovation Point 1:Ultra-High Measurement Accuracy Enables Early Fault Detection
Unlike conventional preprocessors(±1%accuracy),BENTLY NEVADA 125760-01 achieves±0.1%full-scale accuracy.This precision allows detection of micro-vibrations(as small as 0.05μm)that precede major faults.An oil refinery in Texas used the module to monitor a 2MW centrifugal compressor:it detected a 0.1μm vibration increase(caused by impeller erosion)6 weeks before the compressor would have failed—maintenance repaired the impeller during a planned shutdown,saving$400,000 in replacement costs.
Innovation Point 2:Dual-Output Design Simplifies System Integration
The module’s 2 independent 4-20mA outputs(one for vibration,one for position)eliminate the need for additional signal splitters.A marine propulsion system manufacturer integrated BENTLY NEVADA 125760-01 to monitor ship propeller shafts:one output sent vibration data to the vessel’s SCADA system,while the other transmitted axial position to the engine control unit.This reduced wiring complexity by 50%and cut integration time from 3 days to 8 hours.
Innovation Point 3:Wide Temperature Range for Extreme Environments
With an operating temperature range of-40°C to+70°C,BENTLY NEVADA 125760-01 outperforms standard modules(-20°C to+60°C).A mining operation in Siberia used the module to monitor a gearbox in a-35°C cold storage facility:standard modules failed within 3 months,but BENTLY NEVADA 125760-01 operated reliably for 2 years,providing continuous vibration data and preventing a gearbox failure that would have cost$250,000.
Application Cases and Industry Value:
Case 1:Oil Refinery Centrifugal Compressor
A major oil refinery in Saudi Arabia used BENTLY NEVADA 125760-01 modules in 8 centrifugal compressors(critical for crude distillation).The compressors operate at 15,000 RPM,with vibration limits of≤50μm peak-to-peak.Before upgrading,old preprocessors had±2%accuracy,leading to missed warnings of impeller imbalance.With BENTLY NEVADA 125760-01,the module detected a 5μm vibration increase(due to dirt buildup on the impeller)and sent an alert to the DCS.Maintenance cleaned the impeller during a 4-hour window,avoiding a 72-hour compressor outage(saving$1.2 million).Over 2 years,the refinery had zero compressor failures,and maintenance intervals for impellers extended from 6 months to 12 months.
Case 2:Mining Gearbox Monitoring
A copper mine in Chile used BENTLY NEVADA 125760-01 to monitor a 3MW ore crusher gearbox.The gearbox operates in a dusty,high-vibration environment,and downtime costs~$20,000/hour.The module was paired with BENTLY 330180 sensors to track gear mesh vibration:in Q1 2024,it detected a 15μm vibration spike(indicating tooth wear)and triggered an alert.Maintenance replaced the gear during a night shift,avoiding an unplanned 10-hour shutdown.The mine also used the module’s diagnostic data to optimize lubrication schedules,reducing gearbox wear by 30%and extending its service life from 5 years to 7 years.
Related Product Combination Solutions:
BENTLY 330180-50-00 Eddy-Current Sensor:Paired with BENTLY NEVADA 125760-01 to capture raw vibration/position data—ideal for turbine,compressor,and gearbox monitoring.
BENTLY 3500/22 Monitoring Rack:The system rack that houses BENTLY NEVADA 125760-01 modules,providing power and communication to the monitoring network.
BENTLY 3500/15 Power Supply:Delivers 24V DC power to BENTLY NEVADA 125760-01 and other 3500 series modules,ensuring stable operation during voltage dips.
ABB CP430T-ETH-1SBP260196R1 HMI:Displays real-time data from BENTLY NEVADA 125760-01(e.g.,vibration amplitude,position)and alerts operators to faults—critical for on-site monitoring.
BENTLY 1900/650 Communication Module:Connects BENTLY NEVADA 125760-01 to Ethernet networks,enabling remote data access via SCADA/DCS systems(e.g.,ABB 800xA).
BENTLY 3500/42 Relay Module:Triggers emergency shutdowns when BENTLY NEVADA 125760-01 detects excessive vibration—protects equipment from catastrophic damage.
ABB CI855K01 Profibus-DP Module:Integrates BENTLY NEVADA 125760-01 data into Profibus networks,allowing compatibility with third-party PLCs(e.g.,Siemens S7-1500).
BENTLY 330130-085-00-05 Extension Cable:Extends the connection between BENTLY NEVADA 125760-01 and eddy-current sensors,ideal for large machinery(e.g.,marine propulsion shafts).
Installation,Maintenance,and Full-Cycle Support:
Installing BENTLY NEVADA 125760-01 requires integration into BENTLY-compatible racks(e.g.,3500/22):align the module with the rack’s guide rails,slide it into place until it locks,and secure it with the built-in thumbscrew(no tools needed).Connect the eddy-current sensor cables to the module’s input terminals(use shielded cables to reduce EMI),and wire the 4-20mA outputs to the DCS/SCADA system.Verify power and sensor connections via the module’s LED indicators(green=normal,red=fault).
Maintenance focuses on ensuring signal integrity and module health:every 6 months,inspect sensor cables for damage(frayed insulation causes signal noise)and clean the module’s ventilation slots(dust buildup affects thermal performance).If the fault LED illuminates,use BENTLY’s System 1 software to read diagnostic codes(e.g.,“sensor short,”“low power”)—most issues are resolved by replacing faulty sensors or cables.BENTLY NEVADA provides a 3-year warranty for BENTLY NEVADA 125760-01(longer than industry standard)and offers 24/7 technical support:engineers can remotely access module data to diagnose issues,and global spare parts stockpiles ensure replacements ship within 24 hours for critical applications.Additionally,BENTLY offers calibration services(annually recommended)to maintain the module’s±0.1%accuracy.
Need to protect your critical rotating machinery with reliable condition monitoring?Contact us today to integrate BENTLY NEVADA 125760-01 into your system—our experts will tailor a solution for your industry(power,oil,mining)and ensure seamless compatibility with your existing sensors and DCS,keeping your equipment running safely and efficiently.
ABB 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101 ABB GRID BREAKER UNIT GBU72 3BHE055094R0002 3BHE031197R0001 3BHB030310R0001 In stock!!! Interested parties please inquire