Description
Application Scenarios
At a combined-cycle power plant, engineers faced repeated nuisance trips on a 13.8 kV generator neutral-grounding relay whenever the unit was energized. Magnetizing inrush and third-harmonic currents were fooling the older instantaneous relay, forcing operators to disable ground protection during start-up—a dangerous gap. After replacing it with the Woodward IRI1-I5E05D, the plant gained DFFT-based harmonic rejection and a configurable 0.05–5 A operating threshold. The relay now detects true insulation failures down to 50 mA while ignoring transient inrush. Its IDMT inverse-time curve coordinates cleanly with upstream feeder protection, and the two SPDT output contacts independently drive the main breaker trip circuit and a SCADA alarm. Over 22 months of operation, the plant recorded zero false trips and successfully cleared two genuine stator-winding insulation faults before they escalated into ground-fault damage.
Parameters
| Main Parameters | Value/Description |
|---|---|
| Product Model | IRI1-I5E05D |
| Manufacturer | Woodward |
| Product Category | Microprocessor Earth Fault (Ground Fault) Protection Relay |
| Series | IRI High-Technology Range (HighPROTEC) |
| Protection Functions | ANSI 50N / 51N sensitive earth fault, zero-sequence overcurrent |
| Rated CT Secondary Current | 5 A (model suffix “I5”; 1 A version available in series) |
| Operating Threshold Range | 0.05 – 5 A CT secondary, DIP-switch selectable |
| Additional Earth-Fault Function | Restricted earth fault (REF / 64REF) for generator & transformer star points |
| Time Characteristics | Definite-time 0.05–10 s; IDMT inverse-time per IEC 60255 |
| Filtering / Algorithm | DFFT digital filtering; harmonic & DC component rejection; 2nd-harmonic suppression ratio >4 |
| Auxiliary Supply | 230 V AC/DC universal (110 V and 24 V variants available in series) |
| Output Contacts | 2 × SPDT (Form C): 250 V AC / 5 A and 30 V DC / 5 A |
| Input Burden | ≤ 0.2 VA per CT input |
| Frequency Compatibility | 50 Hz / 60 Hz (DIP-selectable) |
| Front Panel Indication | Power, Ready, Earth Fault, Trip, Alarm LEDs + RESET pushbutton |
| Reset Modes | Auto-reset after fault cleared; manual via panel button or external dry contact |
| Mounting | DIN rail / panel / door / 19-inch rack; withdrawable plug-in chassis |
| Dimensions (H × W × D) | 260 × 72 × 138 mm |
| Weight | Approx. 0.7–1.5 kg (varies by configuration) |
| Enclosure Protection | Front panel IP54; internal wiring side IP20 |
| Operating Temperature | −20 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Humidity | 5–95 % RH, non-condensing |
| Setting Method | Front-panel DIP switches + internal code jumpers; no PC or software required |
| Standards & Certifications | CE, UL, IEC 60255, Class I Division 2 |
Technical Principles and Innovative Values
Innovation Point 1 — DFFT Algorithm Eliminates Nuisance Tripping: Unlike electromechanical or basic solid-state relays that respond to the raw waveform, the IRI1-I5E05D uses a Discrete Fourier Transform (DFFT) algorithm to extract only the fundamental-frequency component of the residual current. Harmonics, DC decay, and magnetizing inrush are mathematically filtered out. This means the relay sees real insulation failure—not transient artifacts—dramatically reducing false trips during energization and load switching.Innovation Point 2 — Dual-Characteristic Flexibility for Selective Coordination: The IRI1-I5E05D supports both definite-time (DT) operation from 0.05–10 seconds and inverse definite minimum time (IDMT) curves per IEC 60255. This allows protection engineers to tune the relay for absolute grading with downstream devices in DT mode, or adopt an inverse curve that responds faster to severe faults while remaining stable for minor imbalances—whichever best fits the system coordination study.Innovation Point 3 — Restricted Earth Fault (REF / 64REF) Capability: Beyond basic residual overcurrent, the IRI1-I5E05D can implement restricted earth fault protection for generator star points and transformer neutral connections. By comparing the current in the neutral conductor against the vector sum of the phase CTs, the relay achieves zone-selective sensitivity—detecting faults within the protected zone while remaining securely stable for external faults.Innovation Point 4 — No-Laptop Field Configuration: All operating thresholds, time delays, and frequency selection on the IRI1-I5E05D are set via sealed front-panel DIP switches and internal code jumpers. This eliminates the need for proprietary software, licensing dongles, or a commissioning laptop in the field—a significant advantage for remote sites, hazardous-area installations, and legacy-system retrofits where original configuration tools may no longer be available.Innovation Point 5 — Independent Fail-Safe Operation: The IRI1-I5E05D is a deterministic standalone protection device. Its local microprocessor continuously evaluates CT inputs and initiates tripping within milliseconds, entirely independent of any external communication network or host system. Even if SCADA, DCS, or Ethernet connectivity is lost, the relay continues to protect the asset without interruption.