| Parameter Name | Parameter Value |
|---|
| Parameter Name | Parameter Value |
|---|---|
| Product Model | IRI1-I5E05D |
| Manufacturer | WOODWARD |
| Product Type | Directional Earth Fault Relay |
| Application | Isolated and Compensated Mains |
| Current Input Terminals | 1E1 / 1E2 |
| Voltage Reference Terminals | L1 / N1 |
| Pickup Setting | 0.2 x In (adjustable) |
| Directional Method | Sin / Cos Phase Comparison |
| Forward Trip Delay | Adjustable (tIE> V) |
| Reverse Trip Delay | Adjustable (tIE> R) |
| Test Current Level | 0.4 x In |
| Frequency | 50/60 Hz |
| Output Relays | Alarm / Trip Contacts |
| Mounting Type | DIN Rail / Panel Mount |
| Operating Temperature | -20°C to +55°C (typical) |
| Standards | IEC 60255 Series |
Main Features and Advantages
Directional Discrimination for Selective Protection: The WOODWARD IRI1-I5E05D implements directional earth fault detection using either the sine or cosine method, evaluating the phase relationship between the residual current at terminals 1E1/1E2 and the reference voltage at terminals L1/N1. This allows the relay to distinguish between faults occurring in the forward direction (toward the protected feeder) and those in the reverse direction (toward the busbar or adjacent feeders). By setting independent trip delays for forward and reverse directions, the IRI1-I5E05D enables selective coordination in ring main and parallel feeder arrangements, ensuring that only the faulted section is isolated while healthy sections remain in service.Sensitive Pickup and Adjustable Time Delays: The relay features a pickup threshold set at 0.2 x In, providing sensitive detection of low-magnitude earth fault currents typical in compensated neutral and high-resistance grounded systems. The forward and reverse trip delays (tIE> V and tIE> R) are independently adjustable, allowing protection engineers to implement time-graded schemes that coordinate with upstream and downstream devices. This adjustability is essential in distribution networks where fault current magnitudes vary with system configuration and where selective tripping is required to maintain supply continuity.Clear Visual Status Indication: The front panel of the IRI1-I5E05D includes a bidirectional LED indicator that provides immediate visual confirmation of the detected fault direction. During normal operation or when the measured phase angle is within the forward marginal region, the LED displays green; when the angle shifts beyond the marginal region into the reverse zone, the LED changes to red. This intuitive indication simplifies commissioning, allows rapid verification of correct CT and VT polarity during commissioning, and assists maintenance personnel in diagnosing the direction of an earth fault without requiring connection to a laptop or configuration software.Robust Construction for Harsh Environments: Built to withstand the electrical and environmental stresses of industrial and utility switchgear environments, the IRI1-I5E05D features a robust enclosure with sealed terminals and internal circuitry designed to reject transients, withstand CT saturation during through-faults, and maintain accuracy across the full operating temperature range. The relay’s design complies with relevant IEC 60255 standards for electromagnetic compatibility and dielectric withstand, ensuring reliable operation in the presence of switching surges, lightning strikes, and power frequency interference common in MV distribution substations.
WhatsApp:+86 18005022363 WeChat: +86 18005022363
Email: