Description
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | ACM21 |
| Manufacturer | Yokogawa Electric Corporation |
| Product Type | General-Purpose Serial Communication Card |
| Compatible Systems | CENTUM CS 1000, CENTUM CS 3000 |
| Communication Interface | RS-232C, 1 port |
| Connection Mode | Point-to-point |
| Communication Mode | Half-duplex |
| Synchronization | Start-stop synchronization |
| Communication Speed | 1200 / 2400 / 4800 / 9600 / 19200 / 38400 bps |
| Transmission Code | ASCII / Binary |
| Character Length | 7 bit / 8 bit |
| Stop Bit | 1 bit / 2 bit |
| Parity Check | None / Odd / Even |
| Connector | D-sub 25 pin (female) |
| Maximum Transmission Distance | 15 m |
| Receive Response Time | Approx. 1 ms after data transmission |
| Isolation | Field-side to system-side optical isolation |
| Current Consumption | 1 A (5.0 V DC) |
| Mounting | Communication Card Nest (combinable with ACM71) |
| Cable Types | KB3 / AKB141 / AKB143 (modem); KB4 / AKB142 / AKB144 (null-modem) |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | –20 °C to +70 °C |
| Humidity | 10% to 90% RH, non-condensing |
| Dimensions (L × W × H) | 125 × 130 × 248 mm |
| Weight | Approx. 0.14 kg |
Main Features and Advantages
Robust serial integration for CENTUM DCS: The Yokogawa ACM21 is purpose-built to integrate serial devices into a CENTUM DCS environment. By handling all serial protocol processing independently, it frees the main FCS controller to concentrate on deterministic control tasks. This architectural separation ensures that data exchange with PLCs, analyzers, and other subsystems never interferes with critical loop control or safety functions.Wide protocol and framing flexibility: With six user-selectable baud rates ranging from 1,200 to 38,400 bps, the Yokogawa ACM21 accommodates everything from slow legacy instruments to higher-speed data terminals. Selectable 7/8-bit character length, 1/2 stop bits, and none/odd/even parity allow precise matching to virtually any RS-232C device. Both ASCII and binary transmission codes are supported, giving engineers full freedom in data representation.Deterministic, low-latency performance: The module’s start-stop synchronization and half-duplex communication deliver predictable data exchange, with a typical receive response time of approximately 1 ms after transmission. For process applications where timely data acquisition directly impacts product quality and safety, this responsiveness is a decisive advantage over generic serial gateways.Electrical isolation and signal integrity: The Yokogawa ACM21 incorporates optical isolation between the field side and the system side, significantly reducing the risk of ground loops and electrical noise corrupting critical control data. The RS-232C interface uses a standard D-sub 25-pin female connector, and Yokogawa’s dedicated KB3/KB4 and AKB-series cables simplify wiring while ensuring signal integrity over the full 15 m transmission distance.Seamless modular installation: Designed for installation in the Communication Card Nest, the Yokogawa ACM21 can be combined with an ACM71 Ethernet communication card in the same nest. This allows a single FCS to support both serial and Ethernet-connected subsystems simultaneously, reducing rack space and total system cost. Compact dimensions and a lightweight form factor make handling and installation straightforward for maintenance teams.
WhatsApp:+86 18005022363 WeChat: +86 18005022363
Email: