Description
Technical Specifications
| Parameter Name | Parameter Value |
|---|---|
| Product Model | Woodward 9907-175 |
| Manufacturer | Woodward |
| Product Type | Load Sharing Module (PWM/Caterpillar) |
| Power Supply | 18–32 Vdc, approx. 5 W |
| PT Inputs | 3-phase, 100–240 Vac line-to-line, 50–400 Hz |
| CT Inputs | 3-phase, 3–7 Arms at full load |
| Load Sharing Input | 0–3 Vdc into 25 kΩ (isochronous mode) |
| Output Type | PWM (pulse-width modulated) for Caterpillar speed control |
| Droop Range | No-load to full-load output reduction |
| Operating Temperature | -40°C to +70°C |
| Dimensions | 273.6 × 214.1 × 59.2 mm |
| Weight | Approx. 1.36–1.4 kg |
| Approvals | EC Compliant, UL/cUL Listed |
Main Features and Advantages
Cross-platform load sharing for mixed engine fleets: The Woodward 9907-175 is purpose-built to interface Caterpillar digital speed controls with Woodward power generation accessories, enabling load sharing between Caterpillar-equipped engines and those governed by Woodward electronic controls. This eliminates the need for proprietary Caterpillar load sharing hardware in facilities that operate mixed-brand generator sets, simplifying spare-parts logistics and reducing integration complexity.
PWM output matched to Caterpillar speed control inputs: Unlike analog-output load sharing modules that deliver a ±3 Vdc or 0.5–4.5 Vdc signal, the Woodward 9907-175 generates a pulse-width-modulated output specifically compatible with Caterpillar digital speed control systems. This direct compatibility ensures that Caterpillar engines receive the correct signal format without external signal conversion, preserving response speed and reliability in load-following operations.
Isochronous and droop operation flexibility: The Woodward 9907-175 supports both isochronous load sharing when operating in parallel with other generators, and droop mode for connection to an infinite bus or when paralleled with an isochronously controlled generator set. The external droop switch is wired in series with the auxiliary circuit breaker contact, and droop mode is selected when either contact opens, giving operators a simple, fail-safe method for mode transition.
Robust environmental construction: Tested for salt fog, 95% non-condensing humidity, and vibration up to 4 G, the Woodward 9907-175 is suitable for marine, offshore, and remote power generation environments. The wide -40°C to +70°C operating range and IP43-rated enclosure compatibility ensure reliable performance in harsh industrial conditions.