ABB Bailey INICT13A Infi-Net1

The ABB Bailey INICT13A is an Infi-Net to Computer Transfer Module (ICT) belonging to the Bailey INFI 90 and Symphony Harmony distributed control system (DCS) family. It serves as the critical communication bridge between the proprietary INFI-Net control network and host computer systems, performing protocol conversion and bidirectional data transfer for supervisory monitoring, engineering configuration, and historical data collection.

Category:
Contact Us WhatsApp / Wechat:+8618150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com

Description

 

Application Scenarios

In a thermal power plant running an INFI 90 DCS commissioned in the early 2000s, the operator station suddenly loses all process data—boiler temperatures, turbine pressures, and feedwater flows freeze on the HMI. The control room is blind, and operators must switch to local manual control while maintenance scrambles to diagnose the issue. The fault traces back to the INICT13A module, the sole gateway between the INFI-Net control network and the plant’s supervisory computers. Because the module is obsolete and no spare is on the shelf, the plant faces either a costly system migration or an extended outage. This scenario is increasingly common as aging INFI 90 installations rely on the secondary market to keep critical communication links alive.

 

Parameter

Main Parameters Value/Description
Product Model INICT13A (also written as ICT13A)
Manufacturer ABB (formerly Bailey Controls)
Product Category Infi-Net to Computer Transfer Module (ICT)
System Compatibility Bailey INFI 90, Network 90, Symphony Harmony
Network Side Interface INFI-Net coaxial bus (75 Ω)
Computer Side Interface SCSI (primary) + RS-232-C (via NTPM01 terminal unit)
Typical Baud Rate 19,200 Baud (RS-232-C)
Supply Voltage 5 VDC (backplane) or 24 VDC (varies by configuration)
Power Consumption Approximately 3–10 W
Operating Temperature 0°C to +60°C (control room/cabinet)
Mounting Standard INFI 90 module mounting unit (MMU), single slot
Lifecycle Status Discontinued; replacement model SPICT13A
MTBF >50,000 hours

 

 

Technical Principles and Innovative Values

  • Innovation Point 1: The Sole Bridge Between Two Worlds. The INICT13A occupies a unique position in the INFI 90 architecture. The control network (INFI-Net) is a proprietary token-ring bus designed for deterministic controller-to-controller communication. Host computers cannot speak this protocol. The INICT13A translates INFI-Net packets into SCSI or RS-232 data streams that engineering workstations, operator stations, and historians can consume. Without it, the DCS is an isolated island with no window into the process.
  • Innovation Point 2: Node Pairing with INNIS21. The INICT13A does not operate alone. It pairs with the INNIS21 network interface slave module to form a complete INFI-Net node. The INNIS21 handles the physical network connection and token passing, while the INICT13A manages the application-layer transfer to the computer side. This division of labor allows the transfer module to focus on data formatting and buffering without being burdened by network timing requirements.
  • Innovation Point 3: Built-In Link Integrity Logic. The module includes hardware-level CRC validation, link self-checking, and automatic retransmission during bus fluctuations. This logic runs on the board’s own circuitry rather than consuming controller CPU cycles, ensuring that heavy supervisory data polling does not degrade the real-time performance of control loops.

 

Application Cases and Industry Value

A 300 MW coal-fired power unit in central China experienced a failure of its INICT13A module in December, causing the entire unit’s INFI 90 operator stations to go dark. With no spare on site and the OEM’s lead time exceeding 40 days, the plant was forced to operate the boiler and turbine on local manual controls, significantly increasing safety risk and reducing load-following capability. A refurbished INICT13A was sourced from the secondary market and installed within days. After restoring the module and verifying node addressing, the operator stations recovered full process visibility. The plant’s instrumentation team subsequently added two spare INICT13A units to their critical spares inventory, recognizing that this single module is a single point of failure for the entire supervisory layer.

 

Related Product Combination Solutions

  • INNIS21: The network interface slave module that pairs with the INICT13A to form a complete INFI-Net node. The INNIS21 handles the physical layer; the INICT13A handles the computer transfer function.
  • NTPM01: Terminal unit that provides the physical RS-232-C connections for the INICT13A’s computer-side interface.
  • SPICT13A: The officially designated replacement for the INICT13A. While functionally compatible, migration may require configuration adjustments. Suitable for plants planning a phased modernization rather than like-for-like replacement.
  • IIMCP / IMMFP: INFI 90 rack-mounted controller modules that generate the process data the INICT13A transfers to the host level. A healthy INICT13A is meaningless without functioning controllers upstream.
  • INICT03A: The predecessor module that the INICT13A replaced. Plants with very early INFI 90 installations may still encounter the INICT03A in documentation, though the INICT13A is the more capable evolution.

Contact Us WhatsApp / Wechat:+86 18150087953
Phone:+86 18150087953
Email:sales@cxplcmro.com