Description
Application Scenarios
A transmission-substation retrofit had a familiar shape: the old RTU560 was still reading its 560BIR01 and 560AIR01 I/O correctly, but the utility’s new DMS wanted IEC 60870-5-104 over the corporate Ethernet, and the legacy protection IEDs on the bay level still spoke only RS-485 Modbus and a few 60870-5-101 links. Replacing the whole RTU meant new wiring, new cabinets, a new FAT and a shutdown window nobody could promise.The answer was a 560CMR01 R0001. The existing rack, backplane and I/O stayed exactly where they were; the new card went into the same slot, the SD card was loaded with the station configuration and the protocol licenses, and the two Ethernet ports were split — E1 to the operational SCADA network, E2 to the local maintance/HMI segment. CP1 kept the RS-485 IED poll, CP2 stayed as the RS-232 local console for the days the network was deliberately isolated. When the station-clock module 560RTC01 pushed PTP-quality time onto the backplane, the SOE stamps on the binary inputs lined up across every bay instead of drifting a few seconds apart.First warm restart, the SCADA saw the full point list and the old IEDs never noticed a thing. The utility got its 104 uplink and kept its investment — and the only outage was the half-hour it took to swap the card.That is the product’s real job: not “more ports,” but letting a twenty-year-old rack speak the protocol the control room wants today without rewriting the field side.
Parameter
| Parameter | Value / Description |
|---|---|
| Product Model | 560CMR01 R0001 |
| Order / Product ID | 1KGT036200R0001 (Global Commercial Alias; COO Germany, tariff 85176200) |
| Manufacturer | ABB, Grid Automation & Communication (RTU560 product line) |
| Product Category | RTU560 Communication Unit (CMU) — central processor and communications module, not an I/O module |
| Processor | 32-bit ARM Cortex-A8, AM3352 @ 800 MHz, running a real-time operating system. The same die handles interface management, event processing, the time base and the internal database |
| Memory | 128 MByte RAM; 8 MByte boot Flash. Working database and run-time state live in RAM; the boot image is fixed in Flash |
| Configuration Storage | Removable SD card (push-push, SD 2.0 class 2, 4 GByte-class devices used in the field). The station config is read at power-on reset, so a card swap is also a config swap — keep a labelled spare card with every sealed spare module |
| Serial Interfaces | 2 × CP1, CP2; RJ45 connectors, software-selectable RS-232C or RS-485, 200 bit/s to 38.4 kbit/s. One port typically polled the IEDs/sub-RTUs, the other stayed as console or a second legacy link |
| Ethernet Interfaces | 2 × E1, E2; 10/100BaseT, IEEE 802.3, RJ45. Two ports let you segregate the SCADA uplink from the local/HMI or maintenance segment on the same module |
| USB Interface | 1 × Micro-USB 2.0 device port (AB receptacle, up to 480 Mbit/s signalling). Used for local service, firmware/configuration work and web-server access to the module |
| Internal I/O Bus | SPB (Serial Peripheral Bus) over the 48-pole DIN 41612 F-type backplane connector; the 560CMR01 R0001 is the bus master. Every 560xx I/O module in the subrack is its slave |
| Real-Time Clock | Battery-buffered RTC, CR2032 3V lithium, cited life >10 years. Holds time through outages; receives the station time-base from a 560RTC0x on the backplane for SOE synchronisation |
| Time Resolution | 1 s from the local RTC; with backplane time-sync the RTU560 event timebase resolves to 1 ms — the number that turns a trip record into evidence |
| Backplane Load | 5 V DC @ 500 mA; 24 V DC @ 3 mA — drawn from the rack power, not a separate supply |
| Status Indication | RUN (green), ERR (red), T (serial Tx), R (serial Rx), S (link speed), L (Ethernet link/activity) on the front panel. First-pass diagnosis needs no laptop |
| Mechanical | 3U Eurocard format, 4R front-panel width ≈ 20 mm; faceplate 206 × 40 × 143 mm (20.6 × 4.0 × 14.3 cm). Net weight 0.158 kg, boxed/shipping weight ≈ 0.215 kg |
| Mounting | Plug-in to the RTU560 subrack backplane; the module occupies the CMU slot in the rack plan. Hot insertion is a system-level decision — see the maintenance section |
| Environment | –25 °C to +70 °C operating; start-up allowed down to –40 °C; survival to +85 °C for up to 96 hours. 5–95% RH non-condensing |
| EMC / Ruggedness | Industrial EMC per IEC 61000-4-x: ESD 8 kV air / 6 kV contact, radiated 10 V/m, EFT 4 kV, surge 2 kV, conducted 10 V, impulse magnetic 2.5/1 kV. Designed for the substation electromagnetic environment, not the office closet |
| Security Variant | R0001 = standard network-security feature set. R0002 adds the security chip and the advanced network-security functions — do not mix them in a redundant pair without a deliberate design decision |
| Protocols | IEC 60870-5-101 / -103 / -104, DNP3, Modbus (master/slave configurations) and the RTU560 internal database/SPB traffic. Protocol and function licenses, and the SD card itself, are not included with the bare module — confirm the license set before you commission |
| Diagnostics | Per-port LEDs, web-server dialog over LAN/USB, and the RTU560 event/status data visible to the engineering tool. The module reports its own health and the I/O-bus state separately |
Two ordering traps are worth a headline. First, the SD card and the protocol licenses are not part of the module shipment — a bare 560CMR01 R0001 on the bench will boot, but it will not speak 104 until the card and license are present. Second, the two security revisions are not plug-alike: R0001 and R0002 share the footprint and the port map, but a redundant pair running mismatched security levels is a configuration you will be explaining to an auditor. Match the revision you already have.
Technical Principles and Innovative Values
Innovation Point 1 — One module is the whole station, by design. The 560CMR01 R0001 does not sit beside a CPU; it is the CPU of the RTU560. It masters the SPB I/O bus, owns the internal database, stamps the events and drives the uplink protocols. That concentration is why the rack stays small and why a single spare card restores the whole site — but it also explains the discipline: you protect this module because there is no fallback inside the chassis.Innovation Point 2 — The config rides on the SD card, not in the solder. At power-on reset the module reads the station configuration from the removable card. Swap the card and you change the station personality; clone the card and you have a ready-to-run disaster-recovery image. In a fleet of identical RTUs this is a deployment superpower — one master image, labelled cards, no per-module commissioning marathon.Innovation Point 3 — Serial and Ethernet are first-class equals, not an afterthought port. CP1 and CP2 are independently selectable RS-232 or RS-485 at up to 38.4 kbit/s, while E1 and E2 are independent 10/100BaseT. A single 560CMR01 R0001 can therefore hold a legacy RS-485 IED ring and a modern 104 uplink at the same time. That is the exact trick that makes brownfield substation and pipeline work solvable without a second gateway.Innovation Point 4 — The RTC is backed, but the accuracy comes from the backplane. The on-board CR2032 keeps the clock walking through a blackout; the 560RTC0x on the subrack backplane supplies the station time-base that the CMU distributes to the I/O modules. The result is millisecond-class SOE alignment across every binary input in the rack — the difference between “something tripped around 14:22” and a sequence you can defend to a regulator.Innovation Point 5 — Security is a hardware revision, not a software checkbox. R0001 gives you the standard network-security posture; R0002 adds a dedicated security chip and the advanced feature set. In an era where utility OT networks are no longer air-gapped by assumption, that split lets you stage the upgrade without changing the port layout, the rack or the wiring. It also means the spare on the shelf must match the security tier you deployed.