Product Overview
The Allen-Bradley 1756-L63S is a GuardLogix Safety Partner controller in the Rockwell Automation Logix5000 family, supplied with 8 MB of user memory. It is one half of a redundant GuardLogix safety system: the Allen-Bradley 1756-L63S contains the safety memory and the safety runtime, but it is not a standalone controller and cannot execute a safety application by itself. In a compliant architecture it is installed in the same chassis as a Primary controller—a 1756-L61, L62, L63, L64 or L65—and takes over execution of the safety tasks within one task period of the Primary detecting a fault. This division of roles is the reason the Allen-Bradley 1756-L63S is described as a Safety Partner rather than as a processor in its own right.The safety capability of the Allen-Bradley 1756-L63S is built on a dual-channel, fault-tolerant architecture. Two processors execute the safety application in lockstep, compare results, and drive two sets of safety outputs; any disagreement forces the outputs to a safe state. The system is certified to IEC 61508 SIL 3, EN 954-1 / ISO 13849-1 PL e, and EN 62061 SIL CL 3, with a proof-test interval of 20 years and a safety application scan time of 1 ms. The controller supports up to 4,000 I/O points, 512 program files, 1,000 tasks and 250 phases, and its event task can handle 12 channels with a 500 µs period and 250 µs response time—performance that places it well inside the timing requirements of most machine-safety and process-safety shutdown functions.Configuration and programming are handled in Studio 5000 Logix Designer / RSLogix 5000 (version 16 or later, revision 16.03 or later) using the GuardLogix safety add-on profile, with a dedicated safety password protecting the safety portion of the project. Safety I/O is connected over CIP Safety via EtherNet/IP or ControlNet through a 1756-EN2T, 1756-EN2TR or 1756-CN2R communication module. The Allen-Bradley 1756-L63S carries three status LEDs for controller health, safety status and I/O health, together with an LCD status display on the module face, and it supports the full Logix5000 instruction set for both standard and safety programming.
Technical Specifications
| Parameter | Value |
|---|---|
| Product Model | 1756-L63S (Catalog 1756-L63S, Series A / B) |
| Manufacturer | Rockwell Automation / Allen-Bradley |
| Product Type | GuardLogix Safety Partner Controller |
| User Memory | 8 MB (standard + safety memory combined) |
| Controller Role | Safety Partner only; requires 1756-L61/L62/L63/L64/L65 as Primary |
| Architecture | Dual-channel, fault-tolerant lockstep processors |
| Safety Certification | IEC 61508 SIL 3; EN 954-1 / ISO 13849-1 PL e; EN 62061 SIL CL 3 |
| Proof Test Interval | 20 years |
| Safety Task Period | 1 ms |
| Event Task | 12 channels, 500 µs period, 250 µs response time |
| Maximum I/O | 4,000 points |
| Program Files | 512 |
| Tasks | 1,000 |
| Phases | 250 |
| Standard Instruction Set | Full Logix5000 |
| Safety I/O Protocol | CIP Safety over EtherNet/IP or ControlNet |
| Communication Modules | 1756-EN2T, 1756-EN2TR, 1756-CN2R |
| Programming Software | Studio 5000 Logix Designer / RSLogix 5000 v16 or later (rev 16.03+) |
| Configuration | Safety password protected; GuardLogix add-on profile |
| Indicators | Controller status, safety status, I/O status LEDs; LCD status display |
| Power Dissipation | 12 W |
| Shock / Vibration | 30 G operating; 2 G @ 10–500 Hz |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Storage Temperature | −40°C to 85°C |
| Relative Humidity | 5% to 95%, non-condensing |
| Enclosure Rating | Open style (none) |
| Certifications | UL, CSA, CE, C-Tick, FM, GOST, KC, RCM, ABS, DNV, GL, LR |
| Lifecycle / Status | Discontinued (obsolete); available as refurbished/new-surplus |
| Warranty | 1 year |
WhatsApp:+86 18005022363 WeChat: +86 18005022363
Email: